EUVIMEDEUVIMED entdecken
Crossref

Postoperative Recovery and Airway Morbidity After Laryngeal Mask Airway Protector in Gynaecological Laparoscopy

Shahnaz Islam, AKM Rakibuzzaman, Shohana Binte Shamiul, Shazia Zafrin, Tushar Das, Aklima Sultana Suravi, Mir Shahadat Hossain, Md. Karimul Hasan, Mahin Muntakim

International Journal of Drug Delivery Technology · 17.07.2026 · 16 (68s)

DOI: 10.25258/ijddt.16.68s.33 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 17.07.2026. Verfasst von Shahnaz Islam und 8 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Postoperative airway morbidity, including sore throat, hoarseness of voice and dysphagia, is a recognized complication of endotracheal intubation following gynaecological laparoscopy. The laryngeal mask airway (LMA) protector, a second-generation supraglottic device, may offer advantages in terms of reduced airway trauma and faster postoperative recovery. This study aimed to evaluate and compare postoperative recovery time and airway morbidity between the LMA protector and the endotracheal tube in patients undergoing gynaecological laparoscopy.

Methods

A quasi-experimental study was conducted at the Gynaecological Operation Theatre, Bangladesh Medical University, from April 2024 to September 2025. Sixty female patients aged 18 to 40 years with ASA physical status I to II were allocated into Group E (endotracheal tube, n=30) and Group L (LMA protector, n=30). Recovery time was measured using the Aldrete score (score of 9/10). Postoperative sore throat, hoarseness of voice and dysphagia were recorded at 24 hours. Airway trauma, duration of anaesthesia and surgery and pulmonary aspiration were also documented. Data were analyzed using SPSS version 26.

Results

Intraoperative haemodynamic parameters remained stable in both groups, although the LMA Protector was associated with significantly lower mean arterial pressure and heart rate following airway device insertion and after extubation. Mean recovery time was significantly shorter in Group L (13.7 ± 1.4 minutes) compared to Group E (16.7 ± 1.9 minutes; p=0.001). Sore throat was significantly less frequent in Group L (16.7%) than in Group E (40%; p=0.045). Airway trauma and dysphagia were more common in Group E, though differences were not statistically significant. Hoarseness of voice was rare in both groups, with no significant difference. No pulmonary aspiration was observed. Procedural durations were comparable between groups.

Conclusion

The LMA protector is associated with significantly shorter recovery time and lower incidence of postoperative sore throat compared to endotracheal intubation, supporting its role as a preferred airway device for reducing postoperative airway morbidity in gynaecological laparoscopy.

Zitieren

APA

Islam, S., Rakibuzzaman, A., Shamiul, S. B., Zafrin, S., Das, T., Suravi, A. S., Hossain, M. S., Hasan, M. K., & Muntakim, M. (2026). Postoperative Recovery and Airway Morbidity After Laryngeal Mask Airway Protector in Gynaecological Laparoscopy. International Journal of Drug Delivery Technology, 16(68s). https://doi.org/10.25258/ijddt.16.68s.33

Vancouver

Islam S, Rakibuzzaman A, Shamiul SB, Zafrin S, Das T, Suravi AS, et al. Postoperative Recovery and Airway Morbidity After Laryngeal Mask Airway Protector in Gynaecological Laparoscopy. International Journal of Drug Delivery Technology. 2026;16(68s). doi:10.25258/ijddt.16.68s.33

BibTeX
@article{Islam2026,
  author = {Islam, Shahnaz and Rakibuzzaman, AKM and Shamiul, Shohana Binte and Zafrin, Shazia and Das, Tushar and Suravi, Aklima Sultana and Hossain, Mir Shahadat and Hasan, Md. Karimul and Muntakim, Mahin},
  title = {Postoperative Recovery and Airway Morbidity After Laryngeal Mask Airway Protector in Gynaecological Laparoscopy},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {68s},
  doi = {10.25258/ijddt.16.68s.33}
}
Kostenlos starten →