Quality by Design (QbD) Approach for Optimization and Validation of a Stability Indicating RP-HPLC Method for the Determination of Aprocitentan in Pharmaceutical Dosage Forms
International Journal of Drug Delivery Technology · 16.07.2026 · 16 (65s)
DOI: 10.25258/ijddt.16.65s.139 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 16.07.2026. Verfasst von Neerudu Sairam und 1 weiteren Autor:innen.
Abstract (Originalsprache)
A simple, rapid, and stability-indicating reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the estimation of aprocitentan, a dual endothelin receptor (ETA/ETB) antagonist, in tablet dosage form using a Quality by Design (QbD) approach. Critical process parameters flow rate, organic phase proportion, and column temperature were optimized using a central composite design (CCD) within a response surface methodology framework, with retention time, theoretical plate count, and tailing factor selected as critical quality attributes. A quadratic model best described the relationship between the process parameters and retention time (adjusted R² = 0.9944), and a design space meeting the analytical target profile was established. Chromatographic separation was achieved on a Kromasil C18 column (250 × 4.6 mm, 5 μm) using 0.01N KH2PO4 buffer and acetonitrile (70:30 v/v) as mobile phase at a flow rate of 1.0 mL/min, column temperature of 30°C, and UV detection at 230 nm; aprocitentan eluted at a retention time of 2.465 min. The method was validated as per ICH Q2(R1) guidelines for specificity, linearity, precision, accuracy, robustness, and sensitivity. Linearity was demonstrated over 3.125–18.75 μg/mL (r² = 0.999; y = 56297x + 5272.9). System and method precision (%RSD) were 0.5% and 0.2%, respectively, and mean recovery was 99.64% (range 98.0–102%). LOD and LOQ were 0.02 and 0.05 μg/mL, respectively. The QbD-optimized RP-HPLC method is simple, economical, precise, and accurate, and is suitable for routine quality control analysis of aprocitentan in pharmaceutical dosage forms.
Zitieren
APA
Sairam, N., & Ramaiah, S. (2026). Quality by Design (QbD) Approach for Optimization and Validation of a Stability Indicating RP-HPLC Method for the Determination of Aprocitentan in Pharmaceutical Dosage Forms. International Journal of Drug Delivery Technology, 16(65s). https://doi.org/10.25258/ijddt.16.65s.139
Vancouver
Sairam N, Ramaiah S. Quality by Design (QbD) Approach for Optimization and Validation of a Stability Indicating RP-HPLC Method for the Determination of Aprocitentan in Pharmaceutical Dosage Forms. International Journal of Drug Delivery Technology. 2026;16(65s). doi:10.25258/ijddt.16.65s.139
BibTeX
@article{Sairam2026,
author = {Sairam, Neerudu and Ramaiah, Sivakumar},
title = {Quality by Design (QbD) Approach for Optimization and Validation of a Stability Indicating RP-HPLC Method for the Determination of Aprocitentan in Pharmaceutical Dosage Forms},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {65s},
doi = {10.25258/ijddt.16.65s.139}
}
EUVIMED