Cyto-Histopathological Correlation of Breast Lesions using the IAC Yokohama System
International Journal of Drug Delivery Technology · 06.07.2026 · 16 (62s)
DOI: 10.25258/ijddt.16.62s.20 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 06.07.2026. Verfasst von Jhilik Bhakat und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Breast carcinoma has become the leading malignancy among women in many Indian metropolitan areas. Fine Needle Aspiration Cytology (FNAC) is a rapid and cost-effective diagnostic tool, but its effectiveness depends on standardized reporting. The IAC Yokohama System (2016) was introduced to provide a uniform five-tier classification to improve communication between cytopathologists and clinicians.
Aim
The main aim of the study is to: 1. Apply the IAC Yokohama system for the diagnostic assessment and subsequent categorization of FNA samples and correlate them with histopathology examination (HPE); 2. Calculate ROM; 3. Calculate p-value.
Objectives
To categorize breast FNAC samples using the five-tier IAC Yokohama System. To perform cytohistopathological correlation to assess the Risk of Malignancy (ROM) for each category. To determine the sensitivity, specificity, and overall diagnostic accuracy of the system.
Methods
A retrospective analysis was conducted over a two-year period (June 2019 to May 2021) involving 205 breast FNAC samples. Cases were classified according to the Yokohama categories: Insufficient (C1), Benign (C2), Atypical (C3), Suspicious (C4), and Malignant (C5). Histopathological correlation was available for 110 cases. Statistical analysis, including the calculation of sensitivity, specificity, and Risk of Malignancy (ROM), was performed using the chi-square test (P < 0.001).
Results
The majority of patients (46.8%) were in the 31–40 years age group. The distribution of categories was: C1 (6.89%), C2 (59.0%), C3 (3.28%), C4 (3.28%), and C5 (14.09%). The Risk of Malignancy (ROM) was 0% for C1, 3.07% for C2, and 100% for categories C3, C4, and C5. The system demonstrated a sensitivity of 95.3%, specificity of 100%, and an overall diagnostic accuracy of 94.5%.
Conclusions
The IAC Yokohama System provides a highly reliable and standardized framework for breast cytology reporting. It effectively stratifies the risk of malignancy, showing excellent specificity and sensitivity, which helps clinicians make informed decisions and reduces unnecessary surgical procedures.
Zitieren
APA
Bhakat, J., & H, C. (2026). Cyto-Histopathological Correlation of Breast Lesions using the IAC Yokohama System. International Journal of Drug Delivery Technology, 16(62s). https://doi.org/10.25258/ijddt.16.62s.20
Vancouver
Bhakat J, H C. Cyto-Histopathological Correlation of Breast Lesions using the IAC Yokohama System. International Journal of Drug Delivery Technology. 2026;16(62s). doi:10.25258/ijddt.16.62s.20
BibTeX
@article{Bhakat2026,
author = {Bhakat, Jhilik and H, Chaithra},
title = {Cyto-Histopathological Correlation of Breast Lesions using the IAC Yokohama System},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {62s},
doi = {10.25258/ijddt.16.62s.20}
}
EUVIMED