EUVIMEDEUVIMED entdecken
Crossref

QbD-Optimized Analytical RP-HPLC Method development and validation for Simultaneous Determination of Ritonavir and Nirmatrelvir

Ashish Rathi, Sarita Karole

International Journal of Drug Delivery Technology · 06.07.2026 · 16 (62s)

DOI: 10.25258/ijddt.16.62s.121 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 06.07.2026. Verfasst von Ashish Rathi und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A robust, Quality by Design (QbD) based RP-HPLC method was successfully developed and validated for the simultaneous estimation of ritonavir and nirmatrelvir in pharmaceutical formulation. Method was optimized by twofactor interaction (2FI) factorial design with mobile phase composition (% acetonitrile) and flow rate selected as independent variables and considered as critical method parameter. Separation was achieved on Agilent C18 column under isocratic conditions using a mobile phase comprising of 0.1% TFA and acetonitrile. Detection wavelength was considered as 221 nm due to sensitivity of both drugs. Method validation parameters of developed method were performed in accordance with ICH Q2(R2) guidelines which includes linearity, specificity, precision, robustness, accuracy and sensitivity (LOD and LOQ). The method demonstrated well-resolved, symmetrical peaks with acceptable retention times for both compounds. Excellent linearity was observed over concentration ranges of 10–50 PPM for ritonavir and 15–75 PPM for nirmatrelvir, with R² of 0.999. Accuracy studies % recovery within 98-105% while precision study shows % RSD less than 2% for repeatability, intraday and interday precision. Analysis of variance (ANOVA) revealed that mobile phase and flow rate significantly affected on response variable includes RT, TP and TF. Therefore, proposed QbD-based RP-HPLC method is simple, reliable, precise, and suitable for routine quality control and stability analysis of pharmaceutical formulations.

Zitieren

APA

Rathi, A., & Karole, S. (2026). QbD-Optimized Analytical RP-HPLC Method development and validation for Simultaneous Determination of Ritonavir and Nirmatrelvir. International Journal of Drug Delivery Technology, 16(62s). https://doi.org/10.25258/ijddt.16.62s.121

Vancouver

Rathi A, Karole S. QbD-Optimized Analytical RP-HPLC Method development and validation for Simultaneous Determination of Ritonavir and Nirmatrelvir. International Journal of Drug Delivery Technology. 2026;16(62s). doi:10.25258/ijddt.16.62s.121

BibTeX
@article{Rathi2026,
  author = {Rathi, Ashish and Karole, Sarita},
  title = {QbD-Optimized Analytical RP-HPLC Method development and validation for Simultaneous Determination of Ritonavir and Nirmatrelvir},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {62s},
  doi = {10.25258/ijddt.16.62s.121}
}
Kostenlos starten →