Comparison of the impact of neutral and steep Trendelenburg positions on end-tidal co₂ during pneumoperitoneum in roboticassisted laparoscopic surgeries
International Journal of Drug Delivery Technology · 03.07.2026 · 16 (61s)
DOI: 10.25258/ijddt.16.61s.128 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 03.07.2026. Verfasst von Bharathi B und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Robotic-assisted laparoscopic surgeries frequently require steep Trendelenburg positioning (25–40°) in nearly 70–90% of pelvic procedures to facilitate optimal surgical exposure. Creation of CO₂ pneumoperitoneum and positional change are known to alter respiratory mechanics during general anaesthesia. Evaluating early changes in end-tidal CO₂ following positional change is important for guiding safe intraoperative ventilatory management during robotic surgeries. Aims and objectives: This prospective observational study aims to compare mean end-tidal CO₂ (EtCO₂) values between the neutral supine position and 30° steep Trendelenburg position during pneumoperitoneum in roboticassisted laparoscopic surgeries. The secondary objectives were to assess changes in Minute ventilation required to maintain normocapnia in neutral and 30° steep Trendelenburg positions, and to compare the Peak Airway pressures between the two positions. Materials and Methods: Patients undergoing robot-assisted laparoscopic surgery were selected. Subjects were divided into two groups based on their position the Neutral group and the Steep Trendelenburg group. EtCO2 in neutral position and steep Trendelenburg position after insuflation of gas is measured at 10 min, 20 min, 30 min and other respiratory parameters like minute ventilation and peak airway pressures were also monitored.
Result
There was a significant increase in (EtCO₂) levels in the steep Trendelenburg position. Specifically, at the 30-minute mark, the mean EtCO₂ was 38.85 ± 2.15 mmHg in the Trendelenburg position compared to 33.95 ± 2.79 mmHg in the neutral position. As a secondary outcome, there was a compensatory rise in both Minute Ventilation 40% (mean difference of 2.77 L/min) and Peak airway pressures in the Trendelenburg position, showing a mean difference of 8.65 cmH₂O. Data analysed using paired t-test.
Conclusion
This study concludes that steep Trendelenburg positioning significantly elevates end-tidal CO₂ and peak airway pressures, creating a challenging respiratory environment that necessitates increased minute ventilation in robotic-assisted laparoscopic surgeries.
Zitieren
APA
B, B., L, N. A., Subbarayalu, A., & R, L. (2026). Comparison of the impact of neutral and steep Trendelenburg positions on end-tidal co₂ during pneumoperitoneum in roboticassisted laparoscopic surgeries. International Journal of Drug Delivery Technology, 16(61s). https://doi.org/10.25258/ijddt.16.61s.128
Vancouver
B B, L NA, Subbarayalu A, R L. Comparison of the impact of neutral and steep Trendelenburg positions on end-tidal co₂ during pneumoperitoneum in roboticassisted laparoscopic surgeries. International Journal of Drug Delivery Technology. 2026;16(61s). doi:10.25258/ijddt.16.61s.128
BibTeX
@article{B2026,
author = {B, Bharathi and L, Nishad Ahamed and Subbarayalu, Alagendran and R, Lakshmi.},
title = {Comparison of the impact of neutral and steep Trendelenburg positions on end-tidal co₂ during pneumoperitoneum in roboticassisted laparoscopic surgeries},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {61s},
doi = {10.25258/ijddt.16.61s.128}
}
EUVIMED