Gamma Index Analysis for Volumetric Modulated Arc Therapy (VMAT) Treatment Planning in the Head and Neck Regions with Ring-Mounted Halcyon Machine

V. Chidambaram, Suresh S

International Journal of Drug Delivery Technology · 01.07.2026 · 16 (60s)

DOI: 10.25258/ijddt.16.60s.104 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 01.07.2026. Verfasst von V. Chidambaram und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The complexity of dose delivery in "volumetric modulated arc therapy (VMAT) necessitates patient-specific quality assurance (PSQA). This is especially true in head and neck cancer treatments. Portal dosimetry using an electronic portal imaging device (EPID)" is extensively utilized in VMAT dose verification.

Aim

To assess the feasibility of gamma index analysis in VMAT treatment plans for head and neck cancers with a ring-mounted Varian Halcyon linear accelerator using EPID-based portal dosimetry.

Methods

Retrospective analysis was done for 65 head and neck VMAT treatment plans. The plans were prepared using the "Eclipse Treatment Planning System (TPS)" version 16.1 and Varian Halcyon™ linear accelerator. PSQA was performed using Varian aS1200 EPID. Gamma passing rates (GPR) were assessed at 1%/1 mm, 2%/2 mm, 2%/3 mm, 3%/2 mm, and 3%/3 mm criteria. GPR ≥97% was clinically acceptable as per AAPM TG-218 guidelines.

Results

Gamma passing rates improved gradually with relaxation of dose difference and distance-to-agreement criteria. Majority of the treatment plans yielded high GPR values (>99%) at the 2%/3 mm and 3%/3 mm criteria. Central arch cases showed comparatively lower passing rates at stringent criteria due to greater treatment complexity.

Conclusion

EPID-based portal dosimetry with the Varian Halcyon platform proved effective in ensuring VMAT QA. The 2%/3mm threshold was deemed appropriate for clinical purposes when evaluating patients under head and neck RT treatment

Zitieren

APA

Chidambaram, V., & S, S. (2026). Gamma Index Analysis for Volumetric Modulated Arc Therapy (VMAT) Treatment Planning in the Head and Neck Regions with Ring-Mounted Halcyon Machine. International Journal of Drug Delivery Technology, 16(60s). https://doi.org/10.25258/ijddt.16.60s.104

Vancouver

Chidambaram V, S S. Gamma Index Analysis for Volumetric Modulated Arc Therapy (VMAT) Treatment Planning in the Head and Neck Regions with Ring-Mounted Halcyon Machine. International Journal of Drug Delivery Technology. 2026;16(60s). doi:10.25258/ijddt.16.60s.104

BibTeX
@article{Chidambaram2026,
  author = {Chidambaram, V. and S, Suresh},
  title = {Gamma Index Analysis for Volumetric Modulated Arc Therapy (VMAT) Treatment Planning in the Head and Neck Regions with Ring-Mounted Halcyon Machine},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {60s},
  doi = {10.25258/ijddt.16.60s.104}
}
Kostenlos starten →