Green RP-HPLC Method Development and Validation for Quantification of Delamanid Using Eco-Friendly Solvent System
International Journal of Drug Delivery Technology · 29.06.2026 · 16 (59s)
DOI: 10.25258/ijddt.16.59s.40 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 29.06.2026. Verfasst von Sonali D. Pawar und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Delamanid (OPC-67683) is a nitroimidazo-oxazole anti-tuberculosis agent approved for multidrugresistant tuberculosis (MDR-TB). Existing analytical methods rely on acetonitrile- or methanol-dominant mobile phases that impose significant environmental and occupational health burdens. The application of green analytical chemistry (GAC) principles to delamanid analysis remains unaddressed in the published literature.
Objective
To develop, optimise, and validate a rapid, sensitive, and environmentally sustainable reversed-phase highperformance liquid chromatography (RP-HPLC) method for the quantification of delamanid in bulk drug substance and pharmaceutical tablet dosage form, employing an ethanol–Milli-Q water binary mobile phase as an eco-friendly alternative to conventional organic solvents.
Methods
Chromatographic separation was achieved on a Waters Symmetry® C18 column (250 × 4.6 mm, 5 µm) using an isocratic mobile phase of ethanol:Milli-Q water (60:40, v/v) at a flow rate of 1.0 mL/min, with UV detection at 320 nm. Method optimisation was conducted by systematically varying mobile phase composition (50:50 to 65:35, v/v) and flow rate (0.8–1.2 mL/min). Validation was performed in accordance with ICH Q2(R2) guidelines (2022). Greenness was assessed using AGREE, GAPI, Analytical Eco-Scale, and NEMI tools.
Results
The optimised method produced a retention time of 4.12 ± 0.03 min, theoretical plate count of 7,842, and tailing factor of 1.12. Linearity was demonstrated over 2–20 µg/mL (y = 58,234x + 12,567; r² = 0.9996). The LOD and LOQ were 0.18 µg/mL and 0.56 µg/mL, respectively. Accuracy yielded a mean recovery of 99.38 ± 0.47% across 80%, 100%, and 120% spike levels. Precision (%RSD) was < 2.0% for intraday and interday studies. Forced degradation studies confirmed the stability-indicating nature of the method. The AGREE score was 0.82 and the Analytical Eco-Scale score was 89/100, both indicating an excellent green profile.
Conclusion
The validated green RP-HPLC method is specific, linear, accurate, precise, robust, and environmentally sustainable, making it suitable for routine quality control of delamanid in pharmaceutical dosage forms.
Zitieren
APA
Pawar, S. D., Patil, H. R., Panpatil, S. V., & Pawar, S. S. (2026). Green RP-HPLC Method Development and Validation for Quantification of Delamanid Using Eco-Friendly Solvent System. International Journal of Drug Delivery Technology, 16(59s). https://doi.org/10.25258/ijddt.16.59s.40
Vancouver
Pawar SD, Patil HR, Panpatil SV, Pawar SS. Green RP-HPLC Method Development and Validation for Quantification of Delamanid Using Eco-Friendly Solvent System. International Journal of Drug Delivery Technology. 2026;16(59s). doi:10.25258/ijddt.16.59s.40
BibTeX
@article{Pawar2026,
author = {Pawar, Sonali D. and Patil, Harshada R. and Panpatil, Satyajeet V. and Pawar, Sakshi S.},
title = {Green RP-HPLC Method Development and Validation for Quantification of Delamanid Using Eco-Friendly Solvent System},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {59s},
doi = {10.25258/ijddt.16.59s.40}
}
EUVIMED