Development, Optimization, and Validation of a Stability-Indicating Reverse Phase HPLC Method for Simultaneous Estimation of Sitagliptin and Metformin in Drug Substance and Combination Formulations
International Journal of Drug Delivery Technology · 15.06.2026 · 15 (57s)
DOI: 10.25258/ijddt.16.57s.43 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 15.06.2026. Verfasst von Nithin Vidiyala und 1 weiteren Autor:innen.
Abstract (Originalsprache)
The quantification of impurities and their degradants in the active pharmaceutical ingredients (APIs) ofsitagliptin and metformin, as well as their combinations, is essential for quality control analysis and stabilityindication for product approval. The method was developed and validated in accordance with the InternationalConference on Harmonisation (ICH) Q2 R2 guidelines. This sensitive method was employed to detect andquantify impurities in both APIs and finished dosage forms for 50 mg/500 mg, 50 mg/850 mg, and 50 mg/1000mg tablet formulations. The same samples of the reference formulations were compared with the genericcompositions. The analytical method developed for sitagliptin quantification utilized Mobile Phase A, consistingof 0.1% orthophosphoric acid (OPA) as mobile phase-A, and Mobile Phase B, comprising 100% acetonitrile in agradient composition. This was conducted using a Waters μBondapak C18 250 × 4.6 mm, 5 μm column with acolumn oven temperature of 50°C, an injection volume of 50 μL, and a flow rate of 1.0 mL/min at 210 nm,employing diluent-1 (acetonitrile and 0.1% OPA 90:10% v/v) and diluent-2 (0.1% OPA solution). MetforminHCL quantification was achieved using a C18 column stationary phase with a mobile phase of potassiumdihydrogen phosphate and n-hexane sulfonic acid at pH 3.5 ±, and methanol in a ratio of 95:5% v/v as MobilePhase A, and 100% acetonitrile as Mobile Phase B, with a flow rate of 0.8 mL/min and an injection volume of10 μL at a column oven temperature of 30°C, utilizing dual wavelengths of 218 nm and 200 nm. The limit ofdetection was established at 0.05% relative to the test concentrations, ensuring the method's capability to detectall known and unknown impurities in both analytes within the APIs and the finished dosage forms.
Zitieren
APA
Vidiyala, N., & M, S. K. (2026). Development, Optimization, and Validation of a Stability-Indicating Reverse Phase HPLC Method for Simultaneous Estimation of Sitagliptin and Metformin in Drug Substance and Combination Formulations. International Journal of Drug Delivery Technology, 15(57s). https://doi.org/10.25258/ijddt.16.57s.43
Vancouver
Vidiyala N, M SK. Development, Optimization, and Validation of a Stability-Indicating Reverse Phase HPLC Method for Simultaneous Estimation of Sitagliptin and Metformin in Drug Substance and Combination Formulations. International Journal of Drug Delivery Technology. 2026;15(57s). doi:10.25258/ijddt.16.57s.43
BibTeX
@article{Vidiyala2026,
author = {Vidiyala, Nithin and M, Srujan Kumar},
title = {Development, Optimization, and Validation of a Stability-Indicating Reverse Phase HPLC Method for Simultaneous Estimation of Sitagliptin and Metformin in Drug Substance and Combination Formulations},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {15},
number = {57s},
doi = {10.25258/ijddt.16.57s.43}
}
EUVIMED