Study of Lightning-Induced Disturbances in Distribution Systems

Shraddha Sharma, Archana Pouranik, Rajeshwari Gour

International Journal of Drug Delivery Technology · 17.06.2026 · 16 (55s)

DOI: 10.25258/ijddt.16.55s.69 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 17.06.2026. Verfasst von Shraddha Sharma und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Overvoltage caused by lightning is also a serious risk to the insulation of distribution feeders, terminals of transformers, and other equipment under protection. This paper suggests a combined MATLAB/Simulink-based model of assessing the direct and indirect lightning surge propagation in a three-phase distribution feeder with coordinated protection elements. The model is a combination of a double-exponential source of lightning, a three-phase coupling of matrices, an RLC feeder response, a nonlinear metal-oxide varistor (MOV) arrester behavior, a grounding impedance, and flashover detection. The simulation of direct surge cases with 20 kV to 1 MV, indirect lightning current-coupling cases, variations in grounding resistance and flashover threshold sensitivities were simulated to evaluate system-level and component-level performance. The results indicate that the MOV arrester dropped the unprotected voltage in the case of the peak current of 40 kA, to 35.47 kV and then to 22.34 kV under the baseline surge case. Final equipment stress was strongly influenced by grounding resistance; with Rg increasing to 10 Ω, the final equipment voltage rose by a factor of 2.5. The integrated direct surge analysis indicated flashover at the 1 MV case, although there was MOV clamping, due to the rise in grounding voltages. The advanced model decreased final equipment voltage by an average of 95.77% to 99.69% across integrated scenarios compared to the basic unprotected feeder model. The paper shows that effective lightning protection evaluation should take into account the feeder coupling, transformer transfer, arrester stress, grounding response, and insulation margin all at the same time.

Zitieren

APA

Sharma, S., Pouranik, A., & Gour, R. (2026). Study of Lightning-Induced Disturbances in Distribution Systems. International Journal of Drug Delivery Technology, 16(55s). https://doi.org/10.25258/ijddt.16.55s.69

Vancouver

Sharma S, Pouranik A, Gour R. Study of Lightning-Induced Disturbances in Distribution Systems. International Journal of Drug Delivery Technology. 2026;16(55s). doi:10.25258/ijddt.16.55s.69

BibTeX
@article{Sharma2026,
  author = {Sharma, Shraddha and Pouranik, Archana and Gour, Rajeshwari},
  title = {Study of Lightning-Induced Disturbances in Distribution Systems},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {55s},
  doi = {10.25258/ijddt.16.55s.69}
}
Kostenlos starten →