Dislocation Resistance of Epoxy Resin and Bioactive Glass Root Canal Sealers Following Diode Laser-Assisted Disinfection: An In Vitro Study
International Journal of Drug Delivery Technology · 04.06.2026 · 16 (53s)
DOI: 10.25258/ijddt.16.53s.18 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 04.06.2026. Verfasst von Anjali R. Dhamale und 4 weiteren Autor:innen.
Abstract (Originalsprache)
AIM: To evaluate and compare the dislocation resistance of Epoxy resin and Bioactive glass sealers following laserassisted root canal disinfection. MATERIALS AND METHODS: Forty-four extracted human intact single-rooted mandibular premolar teeth were decoronated to obtain a standardized root length of 14 mm. Cleaning and shaping was performed using ProTaper Universal rotary file up to size F3 and 2.5% sodium hypochlorite irrigation in between each instrument change. Final irrigation protocol consisted of 5 mL 2.5% NaOCl (30 s), 3 mL 17% EDTA (60 s), followed by 3 mL NaOCl (30 s) and saline flush. Canals were dried with paper points. Laser-assisted disinfection was performed using a 980-nm diode laser with a 200-µm fiber optic tip at 2.4 W in pulsed mode (20 µs pulse duration), delivering 12 J per cycle. Irradiation was done for 20 seconds followed by a 10-second pause, constituting one cycle, and this cycle was repeated three times. Samples were randomly divided into two groups using the lottery method (n = 22): Group 1: Epoxy resin–based sealer (AH Plus) Group 2: Bioactive glass–based sealer (Nishika Canal Sealer BG) Obturation was performed using single cone technique and the respective sealers. Access cavities were sealed with Cavit and stored at 37°C and 100% humidity for one week. Each root was sectioned horizontally into coronal, middle, and apical thirds (2 mm thickness each), yielding a total of 132 specimens. Push-out bond strength was evaluated using a Universal Testing Machine at a crosshead speed of 0.5 mm/min with appropriate plunger diameters for each section. Dislocation resistance (MPa) was calculated by dividing the force at dislodgement (N) by the bonded surface area. Data was analyzed using two-way ANOVA and Tukey’s post hoc test. RESULTS: The epoxy resin–based sealer (Laser with AH Plus) demonstrated significantly higher push-out bond strength compared to the bioactive glass–based sealer (Laser with Nishika Canal BG) (p < 0.001). AH Plus showed mean bond strength values of 3.75 MPa (coronal), 2.63 MPa (middle), and 1.80 MPa (apical), whereas Nishika Canal BG exhibited lower values of 1.51 MPa (coronal), 0.78 MPa (middle), and 0.90 MPa (apical). In both groups, bond strength decreased progressively from coronal to apical thirds. Two-way ANOVA revealed a significant effect of sealer type and root canal section on push-out bond strength (p < 0.05), with a significant interaction between the variables (p < 0.05). Tukey’s post hoc analysis confirmed that AH Plus exhibited significantly higher bond strength than Nishika Canal BG in all root sections. CONCLUSION: Laser-assisted root canal disinfection influenced the push-out bond strength of both sealers. The epoxy resin–based sealer showed significantly higher dislocation resistance than the bioactive glass–based sealer in all root canal thirds. Bond strength was highest in the coronal third for both sealers. The apical third remained the most challenging region for sealer adhesion. Further long-term and clinical studies are required to assess the aging behaviour and clinical performance of bioactive glass–based sealers following laser-assisted disinfection.
Zitieren
APA
Dhamale, A. R., Patil, A. C., Gupta, T., K.S., P., & Nalawade, T. (2026). Dislocation Resistance of Epoxy Resin and Bioactive Glass Root Canal Sealers Following Diode Laser-Assisted Disinfection: An In Vitro Study. International Journal of Drug Delivery Technology, 16(53s). https://doi.org/10.25258/ijddt.16.53s.18
Vancouver
Dhamale AR, Patil AC, Gupta T, K.S. P, Nalawade T. Dislocation Resistance of Epoxy Resin and Bioactive Glass Root Canal Sealers Following Diode Laser-Assisted Disinfection: An In Vitro Study. International Journal of Drug Delivery Technology. 2026;16(53s). doi:10.25258/ijddt.16.53s.18
BibTeX
@article{Dhamale2026,
author = {Dhamale, Anjali R. and Patil, Anand C. and Gupta, Tarasha and K.S., Poornananda and Nalawade, Tejas},
title = {Dislocation Resistance of Epoxy Resin and Bioactive Glass Root Canal Sealers Following Diode Laser-Assisted Disinfection: An In Vitro Study},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {53s},
doi = {10.25258/ijddt.16.53s.18}
}
EUVIMED