An Experimental Investigation of Forced Convective Glazed Photovoltaic-Thermal Solar Collector/Regenerator (FCGPVTSCR) for Liquid Desiccant Regeneration

Alpesh R. Patel, Kalpesh V. Modi

International Journal of Drug Delivery Technology · 12.06.2026 · 16 (53s)

DOI: 10.25258/ijddt.16.53s.158 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 12.06.2026. Verfasst von Alpesh R. Patel und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing demand for energy efficient and environmentally sustainable air-conditioning, and drying systems has led to development of solar assisted liquid desiccant (LD) technologies. In light of this, the current study uses an aqueous CaCl₂ solution to experimentally examine the regeneration and electrical performance of a novel Forced Convective Glazed Photovoltaic–Thermal Solar Collector/Regenerator (FCGPVTSCR) under varying air mass flow rates (ṁ_a ). In the proposed system, a photovoltaic (PV) panel simultaneously acts as solar absorber for thermal energy collection and as source of electrical power generation, while a thin film of weak LD solution (LDS) flows over the PV surface for regeneration. The experimental setup comprised a glazed PV panel with forced air circulation in parallel flow arrangement to enhance simultaneous heat and mass transfer processes. These investigations were carried out in outdoor climate of Valsad at constant LDS flow rate of 15 L/h and ṁ_a of 0.00869, 0.00993 and 0.01118 kg/s. The impact of ṁ_a on temperature rise, moisture removal rate (MRR_reg), regeneration effectiveness, absorber plate temperature and electrical performance was studied. Results indicated that increased solar radiation during peak sunshine hours significantly enhanced moisture removal and thermal characteristics. The average MRR_reg increased from 0.167 kg/h∙m² to 0.194 kg/h∙m² with increasing ṁ_a from 0.00869 kg/s to 0.01118 kg/s, because of improved convective mass transfer. Although the conventional PV panel provided higher electrical output, FCGPVTSCR provided better overall thermo-electrical utilization with peak system efficiency of ≈20–21% confirming its suitability for sustainable LD based cooling and drying applications.

Zitieren

APA

Patel, A. R., & Modi, K. V. (2026). An Experimental Investigation of Forced Convective Glazed Photovoltaic-Thermal Solar Collector/Regenerator (FCGPVTSCR) for Liquid Desiccant Regeneration. International Journal of Drug Delivery Technology, 16(53s). https://doi.org/10.25258/ijddt.16.53s.158

Vancouver

Patel AR, Modi KV. An Experimental Investigation of Forced Convective Glazed Photovoltaic-Thermal Solar Collector/Regenerator (FCGPVTSCR) for Liquid Desiccant Regeneration. International Journal of Drug Delivery Technology. 2026;16(53s). doi:10.25258/ijddt.16.53s.158

BibTeX
@article{Patel2026,
  author = {Patel, Alpesh R. and Modi, Kalpesh V.},
  title = {An Experimental Investigation of Forced Convective Glazed Photovoltaic-Thermal Solar Collector/Regenerator (FCGPVTSCR) for Liquid Desiccant Regeneration},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {53s},
  doi = {10.25258/ijddt.16.53s.158}
}
Kostenlos starten →