Relevance Of Automatic Techniques Including Artificial Intelligence On Radiation Dose Optimization In Computed Tomography

Satnam Singh, Manish Shaw, Harmeet Kaur, Bhavay Sonik, Paramdeep Singh, Jayant Jagtap

International Journal of Drug Delivery Technology · 12.06.2026 · 16 (53s)

DOI: 10.25258/ijddt.16.53s.114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 12.06.2026. Verfasst von Satnam Singh und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AI (Artificial Intelligence) is revolutionizing every aspect of the modern world, including medical imaging. Artificial intelligence is increasingly being employed through machine learning (ML) and deep learning (DL) to address the issue of radiation dose. This study worked on the fundamental facets of computed tomography that have primary control over radiation exposure to determine the relevance of physics-based automatic algorithms and artificial intelligence algorithms used in computed tomography for optimizing radiation dose. For this study, patients were stratified based on BMI, considering basic CT parameters such as kVp selection, tube current modulation (mAs), scan length, pitch, and CT FOV (field of view), which directly affect radiation dose optimization and Radiation dose indices such as CTDIvol, dose length product and effective dose were calculated to know the effectiveness of the techniques. Considering the importance of mAs and kVp, work was mainly done on real time modulation of X-ray tube current and real time automatic kVp selection and fixed value of scan length, pitch, and FOV (field of view) to determine the effectiveness and limitations of current automatic techniques. Finally, the current role and future scope of artificial intelligence for radiation dose optimization in computed tomography were diagnosed. Result: The Mean effective dose ranged from 1.42 mSv (head) to 4.71 (abdomen) and 5.22 mSv (chest). In the case of head CT scans, the effective dose varies across automatic exposures, with real time modulation of kV ranging from 1.210 mSv at a BMI of 16.8 (kg/m2 ) - 2.062 mSv at BMI of 27.7 (kg/m2 ) in an obese patient and 1.5 mSv at BMI of 24 (kg/m2 ) in a patient scanned with a fixed 120 kVp to 2.041 mSv at BMI of 25.7 (kg/m2 ) and 1.810 mSv at BMI of 32.5 (kg/m2 ). While in the abdomen and pelvis it ranged from 2.595 mSv at a BMI of 19 (kg/m2 ) - to 5.655 mSv at a BMI of 29.4 (kg/m2 ). The low dose chest effective dose varies across the automatic exposures with real time modulation of kVp (80 kVp to 140 kVp), from 3.150 mSv for a thin patient with a BMI of 15.6 (kg/m2 ) - to 6.45 mSv for an obese patient with a BMI of 30.4 (kg/m2 ) and with a fixed 100 kVp, the effective dose ranged from 1.120 mSv at a BMI of 14.8 (kg/m2 ) to 4.242 mSv at a BMI of 38.6 (kg/m2 ), while with a fixed 120 kVp, the effective dose ranged from 2.450 mSv at a BMI of 18.7 (kg/m2 ) to 4.242 mSv at a BMI of 38.6 (kg/m2 ) but up to 6.006 mSv at a BMI of 29.5 (kg/m2 ). In the case of cardiac CT scans, the effective dose ranged from 1.17 mSv at a BMI of 23.5 (kg/m2 ), including 1.246 mSv at a BMI of 20.2 (kg/m2 ) - 3.766 mSv at a BMI of 28 (kg/m2 ). Conclusions - AI holds significant promise for reducing radiation exposure in CT scans. AI-based technologies enhance positioning and scan range accuracy through automatic patient centering and delineation, thereby lowering radiation doses and minimizing over-scanning, but the selection of fundamental CT scan parameters is still performed by traditional physics-based automatic techniques which are performing better near the reference tube current/ control Tube current and modify the radiation exposure using scan scout images but more variation in exposure found in obese patients as well as underweight patients. The involvement of AI in AEC may consider fully automating the AEC system or removing AEC limitations but the current absence of FDA-approved AI algorithms to modulate mAs and kVp on AEC by any vendor defines that the scope of AI on automatic MA and KVP modulation is broad but under development Keywords: Artificial Intelligence, Radiation Dose Optimization, Computed Tomography, Automatic Exposure Control, mA modulation, kVp selection.

Zitieren

APA

Singh, S., Shaw, M., Kaur, H., Sonik, B., Singh, P., & Jagtap, J. (2026). Relevance Of Automatic Techniques Including Artificial Intelligence On Radiation Dose Optimization In Computed Tomography. International Journal of Drug Delivery Technology, 16(53s). https://doi.org/10.25258/ijddt.16.53s.114

Vancouver

Singh S, Shaw M, Kaur H, Sonik B, Singh P, Jagtap J. Relevance Of Automatic Techniques Including Artificial Intelligence On Radiation Dose Optimization In Computed Tomography. International Journal of Drug Delivery Technology. 2026;16(53s). doi:10.25258/ijddt.16.53s.114

BibTeX
@article{Singh2026,
  author = {Singh, Satnam and Shaw, Manish and Kaur, Harmeet and Sonik, Bhavay and Singh, Paramdeep and Jagtap, Jayant},
  title = {Relevance Of Automatic Techniques Including Artificial Intelligence On Radiation Dose Optimization In Computed Tomography},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {53s},
  doi = {10.25258/ijddt.16.53s.114}
}
Kostenlos starten →