Development of UI for early diagnosis of Cardiac Autonomic Neuropathy (CAN)

R. Lakshmi, RS. Varsha, Abhirup Shatapatthy, S. Sharanya

International Journal of Drug Delivery Technology · 04.06.2026 · 16 (46s)

DOI: 10.25258/ijddt.16.46s.149 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 04.06.2026. Verfasst von R. Lakshmi und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac Autonomic Neuropathy (CAN) is a progressive complication of Diabetes Mellitus characterized by impaired autonomic regulation of cardiac activity. Early-stage CAN remains clinically silent, limiting the effectiveness of conventional diagnostic tools such as Cardiovascular Autonomic Reflex Tests (CARTs), which require supervised physical maneuvers and controlled environments. This study proposes a non-invasive, engineering-driven framework for early CAN detection using electrocardiogram (ECG)-based nonlinear analysis integrated with a human-centered graphical user interface (GUI). The system incorporates ECG acquisition, finite impulse response bandpass filtering (3–40 Hz), automated PQRST peak detection, RR interval extraction, heart rate variability (HRV) analysis, Poincaré plot parameter computation (SD1, SD2, SD1/SD2 ratio), and segment-wise fractal dimension (FD) estimation. Non-parametric statistical evaluation was performed due to the non-Gaussian nature of biomedical signals. Mann–Whitney U testing demonstrated statistically significant differences confirming strong discriminative capability of nonlinear ECG features. Increased fractal irregularity and altered Poincaré descriptors were consistently observed in CAN-positive subjects, indicating progressive autonomic dysfunction. The modular GUI architecture enables real-time signal visualization, transparent peak verification, structured feature extraction, and automated statistical reporting, reducing clinician workload and improving usability for elderly-friendly screening. Cross-validation across datasets demonstrated reproducibility and robustness of extracted nonlinear features. By integrating biomechanics-based signal modelling, nonlinear statistical analysis, and translational interface design, the proposed framework provides a scalable and patient-centric solution for early CAN screening, with potential extension toward wearable and IoT-enabled remote cardiovascular monitoring systems.

Zitieren

APA

Lakshmi, R., Varsha, R., Shatapatthy, A., & Sharanya, S. (2026). Development of UI for early diagnosis of Cardiac Autonomic Neuropathy (CAN). International Journal of Drug Delivery Technology, 16(46s). https://doi.org/10.25258/ijddt.16.46s.149

Vancouver

Lakshmi R, Varsha R, Shatapatthy A, Sharanya S. Development of UI for early diagnosis of Cardiac Autonomic Neuropathy (CAN). International Journal of Drug Delivery Technology. 2026;16(46s). doi:10.25258/ijddt.16.46s.149

BibTeX
@article{Lakshmi2026,
  author = {Lakshmi, R. and Varsha, RS. and Shatapatthy, Abhirup and Sharanya, S.},
  title = {Development of UI for early diagnosis of Cardiac Autonomic Neuropathy (CAN)},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {46s},
  doi = {10.25258/ijddt.16.46s.149}
}
Kostenlos starten →