Validated Reverse Phase High Performance Liquid Chromatography Approach via Experimental Design for Accurate Embelin Estimation in Pharmaceutical Products
International Journal of Drug Delivery Technology · 04.06.2026 · 16 (45s)
DOI: 10.25258/ijddt.16.45s.117 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 04.06.2026. Verfasst von Monika Dhaka und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Objective
A Box-Behnken experimental design was employed within a quality by design approach (QbD) to develop a rapid and straightforward Reverse-phase high performance liquid chromatography (RP-HPLC) method for quantifying embelin (EMB) in bulk drug and formulations requiring fewer runs for optimization.
Method
Independent variables - flow rate (A), organic solvent ratio (B), and column temperature (C) were optimized with respect to response variables: retention time (Y1), and % recovery (Y2). Statistical significance was confirmed via analysis of variance (ANOVA). Chromatographic separation used a C18 column (250 × 4.6 mm, 5 µm particle size) with an isocratic mobile phase (90:10 v/v) of 0.1% phosphoric acid in methanol (A) and 0.1% phosphoric acid in water (B) at flow rates of 0.6–1.4 ml/min. The method proved simple, sensitive, and precise for routine EMB quantification.
Results
The method demonstrated excellent linearity (R² > 0.999, 125−750 µg/ml), accuracy as (% recovery) 99.146-100.691%, limit of detection (LOD) (0.06825 µg/ml), and limit of quantification (LOQ) (0.20683 µg/ml). It was successfully applied for EMB quantification in nano-formulation.
Conclusion
All validation parameters (linearity, accuracy, recovery, LOD, and LOQ) met acceptance criteria, affirming that RP-HPLC method could be suitably employed for EMB estimation in the bulk drug and nanoformulations.
Zitieren
APA
Dhaka, M., Akhter, H., Kawish, S., Rani, K., Yadav, P., & Hasan, N. (2026). Validated Reverse Phase High Performance Liquid Chromatography Approach via Experimental Design for Accurate Embelin Estimation in Pharmaceutical Products. International Journal of Drug Delivery Technology, 16(45s). https://doi.org/10.25258/ijddt.16.45s.117
Vancouver
Dhaka M, Akhter H, Kawish S, Rani K, Yadav P, Hasan N. Validated Reverse Phase High Performance Liquid Chromatography Approach via Experimental Design for Accurate Embelin Estimation in Pharmaceutical Products. International Journal of Drug Delivery Technology. 2026;16(45s). doi:10.25258/ijddt.16.45s.117
BibTeX
@article{Dhaka2026,
author = {Dhaka, Monika and Akhter, Habban and Kawish, S.M. and Rani, Ketki and Yadav, Priya and Hasan, Noor},
title = {Validated Reverse Phase High Performance Liquid Chromatography Approach via Experimental Design for Accurate Embelin Estimation in Pharmaceutical Products},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {45s},
doi = {10.25258/ijddt.16.45s.117}
}
EUVIMED