Association of Axial Length, CCT, and IOP with Myopia Severity in Young Patients
International Journal of Drug Delivery Technology · 04.06.2026 · 16 (45s)
DOI: 10.25258/ijddt.16.45s.106 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 04.06.2026. Verfasst von Sandeep Kumawat und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Purpose
To assess the relative contributions of axial length (AL), central corneal thickness (CCT), and intraocular pressure (IOP) to myopia severity in young persons.
Methods
This study investigated 356 individuals aged 5-30 with myopia (spherical equivalent < −0.50 D) who visited a tertiary care institution. Subjective refraction, A-scan biometry for axial length, ultrasonic pachymetry for central corneal thickness, and Goldmann applanation tonometry for intraocular pressure were used. To avoid inter-eye correlation bias, only right-eye data were evaluated. One-way ANOVA, multiple linear regression, and Pearson's correlation were used to classify myopia as mild (−0.50 to −3.00 D), moderate (−3.00 to −6.00 D), and high (> −6.00 D). A significance threshold of p < 0.05 was used.
Results
There were 356 eyes that we looked at. The participants were, on average, 21.9 ± 5.4 years old. The average spherical equivalent value was -2.85 D, the axial length was 23.78 ± 1.85 mm, the central corneal thickness was 521.6 ± 42.3 µm, and the intraocular pressure was 16.9 ± 4.2 mmHg. Of the eyes that were tested, 70.2% had mild myopia, 20.2% had moderate myopia, and 9.6% had high myopia. Axial length goes up a lot as myopia gets worse (22.88 ± 0.82 mm low, 24.32 ± 1.05 mm intermediate, 26.91 ± 1.48 mm high; p < 0.001). The eye pressure is higher in people with high myopia (19.8 ± 4.5 mmHg) than in people with intermediate myopia (17.3 ± 3.7 mmHg) and low myopia (15.7 ± 3.1 mmHg; p = 0.01). Central corneal thickness did not differ across groups (p = 0.09). Axial length and spherical equivalent had a strong negative relationship (r = -0.81, p < 0.001), while intraocular pressure had a weak negative relationship (r = -0.26, p = 0.01). There was a 0.22 link between the p-value and the central corneal thickness. The best predictor of myopia severity was axial length (β = -0.77, p < 0.001), followed by intraocular pressure (β = 0.18, p = 0.01) and central corneal thickness (β = -0.12, p = 0.02).
Zitieren
APA
Kumawat, S., Thakur, S. K., & Kumar, R. (2026). Association of Axial Length, CCT, and IOP with Myopia Severity in Young Patients. International Journal of Drug Delivery Technology, 16(45s). https://doi.org/10.25258/ijddt.16.45s.106
Vancouver
Kumawat S, Thakur SK, Kumar R. Association of Axial Length, CCT, and IOP with Myopia Severity in Young Patients. International Journal of Drug Delivery Technology. 2026;16(45s). doi:10.25258/ijddt.16.45s.106
BibTeX
@article{Kumawat2026,
author = {Kumawat, Sandeep and Thakur, Sunil Kumar and Kumar, Rajesh},
title = {Association of Axial Length, CCT, and IOP with Myopia Severity in Young Patients},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {45s},
doi = {10.25258/ijddt.16.45s.106}
}
EUVIMED