Comparative Study of Axial Length Measurement Using A-Scan and B-Scan in Intra Ocular Lens Power Calculation for Cataract Surgery
International Journal of Drug Delivery Technology · 01.06.2026 · 16 (43s)
DOI: 10.25258/ijddt.16.43s.15 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 01.06.2026. Verfasst von Dr. Pabba Harshitha und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Background
The precision of intraocular lens (IOL) power estimate is the paramount factor influencing postoperative refractive results following cataract surgery. In contemporary intraocular lens (IOL) formulations, axial length (AL) significantly influences the final IOL power estimation; even minor inaccuracies in AL can result in clinically significant refractive discrepancies post-surgery. Aims & Objectives: To compare the accuracy of the A-Scan versus B-Scan in measuring the axial length and intraocular lens power in cataract surgery. Methodology: A prospective comparative study was conducted among 214 patients who were aged more than 40 years and came for cataract surgery at the Department of Ophthalmology, R. L. Jalappa Hospital and Research Centre, Kolar.
Results
The mean axial length assessed by B-scan (23.24 ± 0.93 mm) was marginally but considerably greater than that recorded by A-scan (23.18 ± 0.92 mm) (p < 0.001). The A-scan-based IOL power was somewhat greater (20.88 ± 2.49 D) compared to the B-scan-based IOL power (20.73 ± 2.52 D) (p < 0.001). On day 1 and day 30, the two groups' post-operative best-corrected visual acuity was similar (p = 0.67 and p = 0.70, respectively). The mean spherical equivalent at day 30 was nearer to emmetropia in the B-scan group (–0.14 ± 0.43 D) than in the A-scan group (–0.30 ± 0.66 D) (p = 0.044). A much greater percentage of patients attained emmetropia (±0.50 D) in the B-scan group (72.0%) compared to the A-scan group (52.3%) (p = 0.004).
Conclusion
B-scan yielded slightly longer axial length measurements and correspondingly lower calculated IOL power, resulting in refractive outcomes closer to emmetropia.
Zitieren
APA
Harshitha, D. P., & C, D. C. M. (2026). Comparative Study of Axial Length Measurement Using A-Scan and B-Scan in Intra Ocular Lens Power Calculation for Cataract Surgery. International Journal of Drug Delivery Technology, 16(43s). https://doi.org/10.25258/ijddt.16.43s.15
Vancouver
Harshitha DP, C DCM. Comparative Study of Axial Length Measurement Using A-Scan and B-Scan in Intra Ocular Lens Power Calculation for Cataract Surgery. International Journal of Drug Delivery Technology. 2026;16(43s). doi:10.25258/ijddt.16.43s.15
BibTeX
@article{Harshitha2026,
author = {Harshitha, Dr. Pabba and C, Dr. Chaitra M.},
title = {Comparative Study of Axial Length Measurement Using A-Scan and B-Scan in Intra Ocular Lens Power Calculation for Cataract Surgery},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {43s},
doi = {10.25258/ijddt.16.43s.15}
}
EUVIMED