Accuracy and Clinical Utility of Infrared Meibography in the Evaluation of Dry Eye Disease
International Journal of Drug Delivery Technology · 29.05.2026 · 16 (40s)
DOI: 10.25258/ijddt.16.40s.55 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 29.05.2026. Verfasst von Mahendra Kumar Verma und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Background:Dry Eye Disease is a common multi-factorial disorder affecting the tear film and ocular surface. Meibomian gland dysfunction is a major cause of Evaporative dry eye. Conventional diagnostic tests such as Tear Break-Up Time and Schirmer's test evaluate tear function but do not provide information about gland structure. Infrared meibography is a non- invasive imaging technique that allows direct visualization of meibomian gland AIM:To evaluate the accuracy and clinical utility of infrared meibography in the diagnosis and assessment of dry eye disease Methods:A cross-sectional observational study was conducted on 80 patients presenting with symptoms of dry eye. All subjects underwent detailed ocular examination including Ocular Surface Disease Index, slit lamp examination, TBUT, Schirmer's test, and infrared meibography. Meibomian gland morphology was assessed and graded, and findings were correlated with conventional dry eye tests. Result:A significant proportion of patients showed varying degrees of meibomian gland loss. A strong negative correlation was observed between gland loss and TBUT as well as Schirmer values. Increased gland dropout was associated with greater severity of dry eye symptoms. Conclusion: Infrared meibography is a reliable, non-invasive, and clinically useful tool for evaluating meibomian gland structure. It enhances the diagnosis of dry eye disease when used alongside conventional tests and aids in early detection, treatment planning, and disease monitoring
Zitieren
APA
Verma, M. K., Kumari, B., & Kumari, R. (2026). Accuracy and Clinical Utility of Infrared Meibography in the Evaluation of Dry Eye Disease. International Journal of Drug Delivery Technology, 16(40s). https://doi.org/10.25258/ijddt.16.40s.55
Vancouver
Verma MK, Kumari B, Kumari R. Accuracy and Clinical Utility of Infrared Meibography in the Evaluation of Dry Eye Disease. International Journal of Drug Delivery Technology. 2026;16(40s). doi:10.25258/ijddt.16.40s.55
BibTeX
@article{Verma2026,
author = {Verma, Mahendra Kumar and Kumari, Babita and Kumari, Rozy},
title = {Accuracy and Clinical Utility of Infrared Meibography in the Evaluation of Dry Eye Disease},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {40s},
doi = {10.25258/ijddt.16.40s.55}
}
EUVIMED