EUVIMEDEUVIMED entdecken
Fallbericht

Surgical Management of Bilateral Denture-Induced Inflammatory Fibrous Hyperplasia Using Scalpel Excision with Adjunctive 940-nm Diode Laser: A Case Report

Dr Amol Ranjan, Dr Ruchi Pandey, Dr Anchal Varshney, Dr Anju Rana

International Journal of Drug Delivery Technology · 31.03.2026 · 16 (3s)

DOI: 10.25258/ijddt.16.3s.10 ↗

Kurz gefasst

Fallbericht in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 31.03.2026. Verfasst von Dr Amol Ranjan und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Denture-induced inflammatory fibrous hyperplasia (IFH), clinically referred to as epulis fissuratum, is a reactive soft tissue lesion caused by chronic mechanical irritation from ill-fitting or overextended dental prostheses. Bilateral presentation is uncommon and reflects prolonged, symmetrical trauma. Surgical excision with elimination of the etiological factor remains the treatment of choice. Patient Concerns: A 55-year-old female denture wearer presented with progressively enlarging, painless soft tissue overgrowths in the maxillary anterior vestibular region for three months, associated with discomfort during mastication and speech. Diagnosis: Clinical examination revealed bilateral, sessile, firm fibrous masses in the maxillary labial vestibule corresponding to the denture flange. Based on clinical findings, a provisional diagnosis of denture-induced inflammatory fibrous hyperplasia was made and later confirmed by histopathological evaluation.

Interventions

The lesions were surgically excised under local anesthesia using a scalpel for precise removal and preservation of tissue architecture. A 940-nm diode laser was used adjunctively to achieve hemostasis. Histopathological analysis demonstrated parakeratinised stratified squamous epithelium overlying a fibrocellular connective tissue stroma with chronic inflammatory infiltrate. The ill-fitting denture was discontinued, and prosthetic rehabilitation was planned following healing. Outcomes: Postoperative healing was uneventful, with satisfactory soft tissue resolution and no evidence of recurrence during the follow-up period. Lessons: This case highlights the importance of early diagnosis and correction of prosthetic etiological factors in dentureinduced reactive lesions. A combined scalpel and diode laser approach offers precise excision, superior hemostasis, and favorable healing outcomes, particularly in extensive bilateral IFH

Zitieren

APA

Ranjan, D. A., Pandey, D. R., Varshney, D. A., & Rana, D. A. (2026). Surgical Management of Bilateral Denture-Induced Inflammatory Fibrous Hyperplasia Using Scalpel Excision with Adjunctive 940-nm Diode Laser: A Case Report. International Journal of Drug Delivery Technology, 16(3s). https://doi.org/10.25258/ijddt.16.3s.10

Vancouver

Ranjan DA, Pandey DR, Varshney DA, Rana DA. Surgical Management of Bilateral Denture-Induced Inflammatory Fibrous Hyperplasia Using Scalpel Excision with Adjunctive 940-nm Diode Laser: A Case Report. International Journal of Drug Delivery Technology. 2026;16(3s). doi:10.25258/ijddt.16.3s.10

BibTeX
@article{Ranjan2026,
  author = {Ranjan, Dr Amol and Pandey, Dr Ruchi and Varshney, Dr Anchal and Rana, Dr Anju},
  title = {Surgical Management of Bilateral Denture-Induced Inflammatory Fibrous Hyperplasia Using Scalpel Excision with Adjunctive 940-nm Diode Laser: A Case Report},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {3s},
  doi = {10.25258/ijddt.16.3s.10}
}
Kostenlos starten →