Comparative Analysis of Improvement in Bite Force among Partially Edentulous Patients after Completion of Treatment: An Observational Study
International Journal of Drug Delivery Technology · 30.05.2026 · 16 (38s)
DOI: 10.25258/ijddt.16.38s.25 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 30.05.2026. Verfasst von Jayasree Bhaduri und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Aims & Background: To evaluate and compare bite force in partially edentulous patients rehabilitated with fixed dental prosthesis (FDPs) and removable partial dentures (RPDs) using an indigenous piezoelectric transducer-based Real time data acquisition, Force Sensitive Resistor (FSR)–Arduino device. Materials and Methods: Fifty-four patients with posterior partial edentulism were divided into two groups (27 FDP, 27 RPD). Bilateral bite force was measured at baseline and one-week post-insertion using a custom FSR–Arduino device. Each site was recorded three times, and mean values (in Newton) were analysed. Normality was assessed with the Shapiro– Wilk test, and intergroup differences were evaluated using the Mann–Whitney U test.
Results
Baseline bite force was significantly lower on the edentulous side. Post-rehabilitation, the FDP group demonstrated a markedly greater increase (mean Δ ≈ 192 N, p < 0.001) than the RPD group (mean Δ ≈ 18 N, p < 0.05), with a large effect size (Cohen's d > 0.8), highlighting superior functional recovery.
Conclusion
An indigenous real-time data acquisition device (FSR–Arduino device) utilised in the study could prove that the fixed denture prosthesis restores bite force more effectively than removable partial dentures in the short term. Clinical significance: The FSR–Arduino device provides an affordable, objective, and reproducible tool for assessing masticatory performance, enhancing prosthetic evaluation and guiding evidence-based treatment decisions, particularly in settings with limited resources
Zitieren
APA
Bhaduri, J., Rajamani, S., Venugopal, V. N., & Gunasekeran, M. (2026). Comparative Analysis of Improvement in Bite Force among Partially Edentulous Patients after Completion of Treatment: An Observational Study. International Journal of Drug Delivery Technology, 16(38s). https://doi.org/10.25258/ijddt.16.38s.25
Vancouver
Bhaduri J, Rajamani S, Venugopal VN, Gunasekeran M. Comparative Analysis of Improvement in Bite Force among Partially Edentulous Patients after Completion of Treatment: An Observational Study. International Journal of Drug Delivery Technology. 2026;16(38s). doi:10.25258/ijddt.16.38s.25
BibTeX
@article{Bhaduri2026,
author = {Bhaduri, Jayasree and Rajamani, Sinduja and Venugopal, Vidyashree Nandini and Gunasekeran, Manjula},
title = {Comparative Analysis of Improvement in Bite Force among Partially Edentulous Patients after Completion of Treatment: An Observational Study},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {38s},
doi = {10.25258/ijddt.16.38s.25}
}
EUVIMED