EUVIMEDEUVIMED entdecken
Crossref

Optimization of Stereotactic Body Radiation Therapy for Liver Metastases: A Comparative Study of Coplanar and Non-Coplanar VMAT Techniques

Rajhans Kumar, Santosh Kumar, Satya Kumar, Y.P. Singh

International Journal of Drug Delivery Technology · 25.05.2026 · 16 (32s)

DOI: 10.25258/ijddt.16.32s.66 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 25.05.2026. Verfasst von Rajhans Kumar und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study aims to evaluate whether non-coplanar VMAT beam arrangements provide dosimetric advantages over coplanar configurations in stereotactic body radiotherapy (SBRT) for liver metastases.

Methods

We conducted a retrospective review of eleven patients who had received SBRT for liver metastases in our department. Two VMAT SBRT plans were generated per patient using the Monaco version 6.01 TPS, configured for an Elekta Versa HD machine with 6-MV FFF beams. The non-coplanar VMAT (NC-VMAT) plans consisted of three half arcs with couch angles of 15°, 30°, and 350°, using arc spans of 0°–180° counter-clockwise and 180°–179° clockwise. Coplanar VMAT (C-VMAT) plans generated with a half arc. All plan prescribed to 42 Gy in 6 fractions. Dosimetric and technical parameters were collected and statistically compared to assess performance differences between the two planning techniques.. Results:Target coverage metrics, including V100, V95, conformity index (CI), Homogeneity index(HI) and gradient index (GD), were comparable between NC-VMAT and C-VMAT plans. NC-VMAT achieved slightly improved dose homogeneity (HI: 1.17 vs. 1.20) and reduced integral dose. Mean liver dose was lower with NC-VMAT (10.12 ± 2.18 Gy) compared with C-VMAT (11.2 ± 1.84 Gy). Most OAR doses were within RTOG limits for both techniques, with NC-VMAT showing reduced maximum doses to the spinal cord, stomach, heart, and ribs. Overall monitor units were slightly lower for NC-VMAT (2096.6 ± 686.8) than C-VMAT (2239.3 ± 522.6). Conclusion:Non-coplanar VMAT demonstrated modest dosimetric advantages over coplanar VMAT for liver SBRT, including improved dose homogeneity, reduced mean liver dose, lower integral dose, and reduced exposure to several critical organs. Target coverage remained comparable between techniques. These findings suggest that incorporating non-coplanar arcs may provide clinically meaningful dosimetric benefits in liver SBRT planning.

Zitieren

APA

Kumar, R., Kumar, S., Kumar, S., & Singh, Y. (2026). Optimization of Stereotactic Body Radiation Therapy for Liver Metastases: A Comparative Study of Coplanar and Non-Coplanar VMAT Techniques. International Journal of Drug Delivery Technology, 16(32s). https://doi.org/10.25258/ijddt.16.32s.66

Vancouver

Kumar R, Kumar S, Kumar S, Singh Y. Optimization of Stereotactic Body Radiation Therapy for Liver Metastases: A Comparative Study of Coplanar and Non-Coplanar VMAT Techniques. International Journal of Drug Delivery Technology. 2026;16(32s). doi:10.25258/ijddt.16.32s.66

BibTeX
@article{Kumar2026,
  author = {Kumar, Rajhans and Kumar, Santosh and Kumar, Satya and Singh, Y.P.},
  title = {Optimization of Stereotactic Body Radiation Therapy for Liver Metastases: A Comparative Study of Coplanar and Non-Coplanar VMAT Techniques},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {32s},
  doi = {10.25258/ijddt.16.32s.66}
}
Kostenlos starten →