EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Using Angulation of Implanters at 45 Degrees to the Scalp with the Bevel Facing toward the Skin to Enhance Follicular Entry at Minimal Pressure: A Randomized Clinical Trial in Hair Transplantation

Shalini Muthuraj, Rajprakash Bhaskaran, Goutham Vijayakumar, Murugesan Krishnan, Parthiban Saketheraman

International Journal of Drug Delivery Technology · 23.05.2026 · 16 (31s)

DOI: 10.25258/ijddt.16.31s.20 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 23.05.2026. Verfasst von Shalini Muthuraj und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Implanter-based follicular unit extraction (FUE) has improved graft handling and placement precision in hair transplantation. However, insertion angulation and bevel orientation during implantation remain largely operatordependent, with limited evidence supporting standardized biomechanical approaches. Optimizing implantation mechanics may reduce tissue trauma, improve graft stability, and enhance procedural efficiency.

Aim

To evaluate whether using an implanter at 45 degrees to the scalp with the bevel facing toward the skin enhances follicular entry at minimal pressure compared with conventional variable-angle implantation. Materials and Methods: This prospective randomized clinical trial included 50 male patients with androgenetic alopecia (Norwood Grade III–V) undergoing FUE hair transplantation. Participants were randomly allocated into two groups (n = 25 each). The control group underwent implantation using conventional variable angulation and non-standardized bevel orientation. The test group received implantation at a fixed 45-degree angle with the bevel consistently oriented toward the skin. Primary outcome was intraoperative insertion resistance. Secondary outcomes included graft popping rate, implantation time per 1,000 grafts, intraoperative bleeding, and graft malalignment. Statistical analysis was performed using SPSS version 29.0, with p < 0.05 considered significant.

Results

The 45-degree bevel-facing group demonstrated significantly reduced insertion resistance (p < 0.01), lower graft popping rate (2.5% ± 1.2 vs 6.2% ± 1.8; p < 0.001), shorter implantation time (39.8 ± 4.9 vs 46.5 ± 5.4 minutes per 1,000 grafts; p < 0.01), reduced bleeding (p < 0.05), and improved graft alignment (4% vs 18%; p < 0.01) compared with the control group.

Conclusion

Standardizing implanter angulation at 45 degrees with bevel orientation toward the skin significantly enhances intraoperative efficiency and graft stability in FUE hair transplantation. This simple, reproducible modification may optimize implantation biomechanics and improve surgical outcomes.

Zitieren

APA

Muthuraj, S., Bhaskaran, R., Vijayakumar, G., Krishnan, M., & Saketheraman, P. (2026). Using Angulation of Implanters at 45 Degrees to the Scalp with the Bevel Facing toward the Skin to Enhance Follicular Entry at Minimal Pressure: A Randomized Clinical Trial in Hair Transplantation. International Journal of Drug Delivery Technology, 16(31s). https://doi.org/10.25258/ijddt.16.31s.20

Vancouver

Muthuraj S, Bhaskaran R, Vijayakumar G, Krishnan M, Saketheraman P. Using Angulation of Implanters at 45 Degrees to the Scalp with the Bevel Facing toward the Skin to Enhance Follicular Entry at Minimal Pressure: A Randomized Clinical Trial in Hair Transplantation. International Journal of Drug Delivery Technology. 2026;16(31s). doi:10.25258/ijddt.16.31s.20

BibTeX
@article{Muthuraj2026,
  author = {Muthuraj, Shalini and Bhaskaran, Rajprakash and Vijayakumar, Goutham and Krishnan, Murugesan and Saketheraman, Parthiban},
  title = {Using Angulation of Implanters at 45 Degrees to the Scalp with the Bevel Facing toward the Skin to Enhance Follicular Entry at Minimal Pressure: A Randomized Clinical Trial in Hair Transplantation},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {31s},
  doi = {10.25258/ijddt.16.31s.20}
}
Kostenlos starten →