Abstract (Originalsprache)
The global detection of nitrosamine impurities in drug products has created a sustained need for highly selective, fit-forpurpose analytical methods that are explicitly aligned with evolving regulatory expectations for acceptable intake limits and method sensitivity [1-4]. Here we describe the development and validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the quantitative determination of N-nitroso desmethyl trimebutine (NNDT), the identified nitrosamine drug substance related impurity (NDSRI) of trimebutine, in immediate-release trimebutine tablet formulations. Chromatographic separation was achieved on a phenyl-hexyl column using a water-methanol gradient containing ammonium formate and formic acid, and detection was performed in positive-ion electrospray multiple reaction monitoring (MRM) mode using the transitions m/z 424.90 → 364.15 (quantifier) and 424.90 → 246.10 (qualifier). The method was validated following ICH Q2(R2) and the nitrosamine-specific expectations of ICH M7 and USP , covering specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and filter compatibility [4-6]. The limit of detection (LOD, S/N ≥ 3) and limit of quantification (LOQ, S/N ≥ 10) were 0.0821 ppm and 0.2487 ppm, respectively, corresponding to approximately 3% and 10% of the NNDT acceptable intake-based specification of 2.5 ppm in trimebutine tablets derived from a compound-specific acceptable intake of 1500 ng/day. Calibration was linear from LOQ to 150% of the 2.5 ppm specification (r = 1.000), and recovery at three levels (LOQ, 100% and 150%) ranged from 95.4–109.3% with relative standard deviations (RSDs) ≤ 5.0% at LOQ and ≤ 1.4% at higher levels. Method and intermediate precision studies gave total RSD ≤ 1.4% at the specification level, and robustness tests (column temperature, flow rate) confirmed minimal impact of typical analytical variability on assay results. The LOQ located at approximately 10% of the NNDT specification level demonstrates that the procedure is capable, in principle, of monitoring at 10% and 30% of acceptable intake, in line with ICH M7 expectations for nitrosamine control. Overall, the method provides a selective, sensitive and operationally simple LC-MS/MS procedure suitable for routine quality-control of NNDT in trimebutine tablets and for use in nitrosamine control strategies and risk-assessment studies.
Zitieren
APA
Kurella, K. K., & Dadhich, A. S. (2026). Development and validation of an LC-MS/MS method for determination of N-nitroso desmethyl trimebutine in trimebutine tablets. International Journal of Drug Delivery Technology, 16(27s). https://doi.org/10.25258/ijddt.16.27s.26
Vancouver
Kurella KK, Dadhich AS. Development and validation of an LC-MS/MS method for determination of N-nitroso desmethyl trimebutine in trimebutine tablets. International Journal of Drug Delivery Technology. 2026;16(27s). doi:10.25258/ijddt.16.27s.26
BibTeX
@article{Kurella2026,
author = {Kurella, Kiran Kumar and Dadhich, Anima S.},
title = {Development and validation of an LC-MS/MS method for determination of N-nitroso desmethyl trimebutine in trimebutine tablets},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {27s},
doi = {10.25258/ijddt.16.27s.26}
}