EUVIMEDEUVIMED entdecken
Crossref

Cancellous Screw Fixation in an Inverted Triangle Configuration for Fracture Neck of Femur in Adults – A Prospective Observational Study

Sreehari K, Jayachandran N, Binoy S, Shibu R

International Journal of Drug Delivery Technology · 05.05.2026 · 16 (24s)

DOI: 10.25258/ijddt.16.24s.69 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 05.05.2026. Verfasst von Sreehari K und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Treatment for femoral neck fractures is extremely difficult, especially for young adults who have experienced high-energy trauma. For non-displaced intracapsular femoral neck fractures, cannulated screw fixation in an inverted triangle configuration is the preferable surgical approach because of its minimally invasive nature, ease of application, and minimum disruption of the femoral head blood supply. On the other hand, little research has been done on its functional effects in adults. The purpose of this study was to evaluate the functional outcome of treating femoral neck fractures with three cancellous screws in an inverted triangle pattern. MATERIALS AND METHODS This prospective observational study included 34 cases of intracapsular femur neck fractures surgically treated with cancellous screws. Functional outcomes were assessed using the Modified Harris Hip Score. RESULTS The study had 34 patients, with a mean age of 40 years (20-50 years). There were 24 males and 10 females. Road traffic accidents accounted for 64.7% of injuries, followed by slips and falls (23.5%) and falls from heights (11.8%). One instance of superficial infection (2.5%), one instance of screw pullout (2.5%), and two instances of non-union (5.8%) were among the complications. Younger patients (40 years) had 55% Excellent/Good outcomes. At maximum follow-up, 23 patients (67.6%) had excellent results, 5 patients (14.7%) had good results, 4 patients (11.7%) had fair results, and 2 patients (5.8%) had poor results. 82.3% of the patients had good or excellent results. CONCLUSION Cancellous screw fixation with three screws in an inverted triangle pattern is a valid and effective treatment option for intracapsular femoral neck fractures, especially for younger patients and early-presenting patients. Early diagnosis, prompt intervention, and multidisciplinary perioperative care are key to optimizing functional outcome and minimizing complications in this group of patients.

Zitieren

APA

K, S., N, J., S, B., & R, S. (2026). Cancellous Screw Fixation in an Inverted Triangle Configuration for Fracture Neck of Femur in Adults – A Prospective Observational Study. International Journal of Drug Delivery Technology, 16(24s). https://doi.org/10.25258/ijddt.16.24s.69

Vancouver

K S, N J, S B, R S. Cancellous Screw Fixation in an Inverted Triangle Configuration for Fracture Neck of Femur in Adults – A Prospective Observational Study. International Journal of Drug Delivery Technology. 2026;16(24s). doi:10.25258/ijddt.16.24s.69

BibTeX
@article{K2026,
  author = {K, Sreehari and N, Jayachandran and S, Binoy and R, Shibu},
  title = {Cancellous Screw Fixation in an Inverted Triangle Configuration for Fracture Neck of Femur in Adults – A Prospective Observational Study},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {24s},
  doi = {10.25258/ijddt.16.24s.69}
}
Kostenlos starten →