EUVIMEDEUVIMED entdecken
Crossref

Comparison Between Transcerebellar Diameter and Other Prenatal Diameters for Detection of Gestational Age

Ashraf Sobhi Khalil Abolouz, Abdelrahman Hosni Hassan Soliman, Mohamed Shabaan Mahmoud, Mahmoud Mostafa Assem, Ahmed Hussein Mohamed Abdel Aal

International Journal of Drug Delivery Technology · 20.04.2026 · 16 (22s)

DOI: 10.25258/ijddt.16.22s.53 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 20.04.2026. Verfasst von Ashraf Sobhi Khalil Abolouz und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Reliable assessment of gestational age (GA) is critical for appropriate obstetric care, but many pregnant women, particularly in low-resource settings, present for ultrasound late in pregnancy without early dating scans or accurate last menstrual period (LMP) recall. Conventional biometric parameters like biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL) are often influenced by fetal growth abnormalities. Transcerebellar diameter (TCD) has emerged as a potentially more stable predictor of GA, yet limited data compare its efficacy against other parameters across wider gestational ages.

Objective

To evaluate efficacy of TCD among multiple measurements fetal age assessment in second and third trimester.

Methods

A cross-sectional study was conducted on 300 pregnant women between 13 and 40 weeks of gestation with confirmed LMP and first-trimester CRL data. Fetal biometric parameters (TCD, BPD, HC, AC, FL) were measured via obstetric ultrasound. Correlation and regression analyses assessed each parameter's relationship with gestational age, and predictive accuracy was evaluated within ±1 and ±2 weeks.

Results

All parameters showed strong correlation with gestational age (TCD: r = 0.992, R² = 0.984; BPD: r = 0.993, R² = 0.987). The combined model yielded the highest accuracy (R² = 0.997) and predicted GA within ±1 week in 100% of cases. TCD alone had the best single-parameter accuracy (88.3% within ±1 week).

Conclusions

TCD is a highly reliable parameter for second and third trimester gestational age estimation, outperforming other individual biometric indices. Its incorporation into routine ultrasound, particularly alongside other measurements, significantly enhances dating accuracy when early GA confirmation is unavailable.

Zitieren

APA

Abolouz, A. S. K., Soliman, A. H. H., Mahmoud, M. S., Assem, M. M., & Aal, A. H. M. A. (2026). Comparison Between Transcerebellar Diameter and Other Prenatal Diameters for Detection of Gestational Age. International Journal of Drug Delivery Technology, 16(22s). https://doi.org/10.25258/ijddt.16.22s.53

Vancouver

Abolouz ASK, Soliman AHH, Mahmoud MS, Assem MM, Aal AHMA. Comparison Between Transcerebellar Diameter and Other Prenatal Diameters for Detection of Gestational Age. International Journal of Drug Delivery Technology. 2026;16(22s). doi:10.25258/ijddt.16.22s.53

BibTeX
@article{Abolouz2026,
  author = {Abolouz, Ashraf Sobhi Khalil and Soliman, Abdelrahman Hosni Hassan and Mahmoud, Mohamed Shabaan and Assem, Mahmoud Mostafa and Aal, Ahmed Hussein Mohamed Abdel},
  title = {Comparison Between Transcerebellar Diameter and Other Prenatal Diameters for Detection of Gestational Age},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {22s},
  doi = {10.25258/ijddt.16.22s.53}
}
Kostenlos starten →