Imaging Accuracy in Focus: CT Angiography Versus Digital Subtraction Angiography for Intracranial Aneurysm
International Journal of Drug Delivery Technology · 25.04.2026 · 16 (22s)
DOI: 10.25258/ijddt.16.22s.36 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 25.04.2026. Verfasst von Innayat Manzoor und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Digital subtraction angiography (DSA) is the reference standard for intracranial aneurysm evaluation; however, CT angiography (CTA) is increasingly used as a non-invasive alternative.
Aim
To assess the diagnostic concordance and performance of CTA compared with DSA in the evaluation of intracranial aneurysms. Materials and Methods: This observational imaging study included 91 patients who underwent both CTA and DSA. Aneurysm detection, number, location, and circulation involvement were compared. Diagnostic performance indices of CTA were calculated using DSA as the reference standard.
Results
Both CTA and DSA detected aneurysms in 100% of patients. Single aneurysms were present in 76.9%, and multiple aneurysms in 23.1%, with identical distribution on both modalities. CTA demonstrated 100% sensitivity, 25% specificity, 96.7% positive predictive value, and 96.7% overall accuracy. Multivariable regression showed that the number of aneurysms was independently associated with angiographic outcome [(Odds ratio (OR) 2.11; 95% CI 1.05–4.26; P = 0.036)].
Conclusion
CTA demonstrates excellent diagnostic concordance with DSA and can be reliably used as a first-line imaging modality, reserving DSA for complex cases and treatment planning.
Zitieren
APA
Manzoor, I., Munshi, D. A., Hamid, D. M., aftab, D. A., & Ilahi, K. (2026). Imaging Accuracy in Focus: CT Angiography Versus Digital Subtraction Angiography for Intracranial Aneurysm. International Journal of Drug Delivery Technology, 16(22s). https://doi.org/10.25258/ijddt.16.22s.36
Vancouver
Manzoor I, Munshi DA, Hamid DM, aftab DA, Ilahi K. Imaging Accuracy in Focus: CT Angiography Versus Digital Subtraction Angiography for Intracranial Aneurysm. International Journal of Drug Delivery Technology. 2026;16(22s). doi:10.25258/ijddt.16.22s.36
BibTeX
@article{Manzoor2026,
author = {Manzoor, Innayat and Munshi, Dr. Avinash and Hamid, Dr. Mudasir and aftab, Dr Anwar and Ilahi, Khalid},
title = {Imaging Accuracy in Focus: CT Angiography Versus Digital Subtraction Angiography for Intracranial Aneurysm},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {22s},
doi = {10.25258/ijddt.16.22s.36}
}
EUVIMED