Estimation of Ethylene Glycol and Diethylene Glycol in Multicomponent Cough Syrup Containing Salbutamol, Bromhexine and Guaifenesin by GC-FID

Dr. Parag Das, Mr. Satish Samireddi, Mr. Animesh Maity, Mr. Amrit Kumar Rath, Sruti Ranjan Mishra, Mrs. Amrita Nayak, Mrs. Manashi Das

International Journal of Drug Delivery Technology · 25.04.2026 · 16 (19s)

DOI: 10.25258/ijddt.16.19s.24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 25.04.2026. Verfasst von Dr. Parag Das und 6 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Multicomponent cough syrup is indicated for the clearance of thick, purulent sputum associated with acute, chronic, and complicated respiratory conditions, including bronchial asthma, bronchiectasis, and whooping cough. Each 5 mL of Multicomponent cough syrup contains 2 mg of salbutamol, 4 mg of bromhexine hydrochloride, and guaifenesin. Salbutamol acts as a selective β₂-adrenergic agonist, producing bronchodilation by relaxing the bronchial smooth muscles without significantly affecting cardiac β₁-receptors. Bromhexine hydrochloride acts as a mucolytic agent, liquefying and loosening mucus to facilitate its removal from the respiratory tract. Guaifenesin, an expectorant, enhances the volume and decreases the viscosity of bronchial secretions, thereby aiding in the expulsion of mucus and improving airway clearance.

Aim

The purpose of this study was to develop and validate a simple, rapid, and cost-effective gas chromatographic method with flame ionization detection (GC-FID) for the simultaneous quantification of ethylene glycol (EG) and diethylene glycol (DEG) in Multicomponent cough syrup. The analytical procedure involved sample dilution with water and analysis using an Agilent 8890 GC system equipped with a ZB-WAX capillary column (30 m × 0.530 mm, 1.0 µm film thickness), with nitrogen as the carrier gas at a flow rate of 1.5 mL/min. The oven temperature program was optimized as follows: initial temperature 100°C (0 min hold), ramped at 7.8°C/min to 180°C (14 min hold), followed by 30°C/min to 245°C (15 min hold). The injector and detector temperatures were both maintained at 250°C. Under these conditions, the retention times for ethylene glycol and diethylene glycol were found to be 12.0 minutes and 21.0 minutes, respectively. Results and Discussion: The developed GC-FID method was validated according to ICH guidelines, and the parameters such as accuracy, precision, linearity, and robustness were found to comply with the established acceptance criteria. The statistical evaluation of results confirmed the reliability, reproducibility, and suitability of the proposed method for routine quality control analysis.

Conclusion

The validated GC-FID method provides a reliable, efficient, and economical approach for the simultaneous estimation of ethylene glycol and diethylene glycol in Multicomponent cough syrup. This procedure can be effectively employed for routine analytical testing and quality assurance in pharmaceutical laboratories.

Zitieren

APA

Das, D. P., Samireddi, M. S., Maity, M. A., Rath, M. A. K., Mishra, S. R., Nayak, M. A., & Das, M. M. (2026). Estimation of Ethylene Glycol and Diethylene Glycol in Multicomponent Cough Syrup Containing Salbutamol, Bromhexine and Guaifenesin by GC-FID. International Journal of Drug Delivery Technology, 16(19s). https://doi.org/10.25258/ijddt.16.19s.24

Vancouver

Das DP, Samireddi MS, Maity MA, Rath MAK, Mishra SR, Nayak MA, et al. Estimation of Ethylene Glycol and Diethylene Glycol in Multicomponent Cough Syrup Containing Salbutamol, Bromhexine and Guaifenesin by GC-FID. International Journal of Drug Delivery Technology. 2026;16(19s). doi:10.25258/ijddt.16.19s.24

BibTeX
@article{Das2026,
  author = {Das, Dr. Parag and Samireddi, Mr. Satish and Maity, Mr. Animesh and Rath, Mr. Amrit Kumar and Mishra, Sruti Ranjan and Nayak, Mrs. Amrita and Das, Mrs. Manashi},
  title = {Estimation of Ethylene Glycol and Diethylene Glycol in Multicomponent Cough Syrup Containing Salbutamol, Bromhexine and Guaifenesin by GC-FID},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {19s},
  doi = {10.25258/ijddt.16.19s.24}
}
Kostenlos starten →