Comparing the implant stability of dental implants placed using osseodensification drills and conventional drilling: a systematic review and meta-analysis
International Journal of Drug Delivery Technology · 24.04.2026 · 16 (18s)
DOI: 10.25258/ijddt.16.18s.27 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 24.04.2026. Verfasst von Dr Chathurika G und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Implant site preparation affects primary stability and early osseointegration of dental implants. Conventional subtractive drilling is widely used in routine clinical practice. Osseodensification has been introduced to compact bone and improve mechanical engagement, but comparative evidence remains inconsistent.
Purpose
To compare implant stability (ISQ) and insertion torque for implants placed with osseodensification versus conventional drilling across time points and anatomical sites.
Methods
Five electronic databases were searched from inception to June 2025. Human clinical and in vitro comparative studies were eligible when they reported ISQ and/or insertion torque for osseodensification and conventional drilling. Risk of bias was assessed using validated tools for randomized and non-randomized studies. Meta-analysis was performed in Stata 17 using a random-effects model. Mean differences with 95% confidence intervals were calculated, and heterogeneity was assessed with I².
Results
Six studies were included. Osseodensification produced higher ISQ values than conventional drilling immediately after placement (MD +5.96; 95% CI 2.78 to 9.13) and at six months (MD +4.45; 95% CI 1.17 to 7.74). Insertion torque values were also higher with osseodensification with the largest differences reported in posterior and maxillary sites. Heterogeneity was substantial across several comparisons.
Conclusion
Osseodensification improves mechanical stability compared with conventional drilling. Further trials with standardized drilling protocols and outcome assessment are required. Clinical implications: Osseodensification may be considered to enhance primary stability particularly in lowdensity bone and posterior maxillary regions.
Zitieren
APA
G, D. C., S, D. M. K., N, D. S., N, D. P., Umashankar, D. P., & Tripathi, D. A. (2026). Comparing the implant stability of dental implants placed using osseodensification drills and conventional drilling: a systematic review and meta-analysis. International Journal of Drug Delivery Technology, 16(18s). https://doi.org/10.25258/ijddt.16.18s.27
Vancouver
G DC, S DMK, N DS, N DP, Umashankar DP, Tripathi DA. Comparing the implant stability of dental implants placed using osseodensification drills and conventional drilling: a systematic review and meta-analysis. International Journal of Drug Delivery Technology. 2026;16(18s). doi:10.25258/ijddt.16.18s.27
BibTeX
@article{G2026,
author = {G, Dr Chathurika and S, Dr Madhan Kumar and N, Dr Shanmuganathan and N, Dr Parthasarathy and Umashankar, Dr Prathiyun and Tripathi, Dr Anushka},
title = {Comparing the implant stability of dental implants placed using osseodensification drills and conventional drilling: a systematic review and meta-analysis},
journal = {International Journal of Drug Delivery Technology},
year = {2026},
volume = {16},
number = {18s},
doi = {10.25258/ijddt.16.18s.27}
}
EUVIMED