A Comparative Study Between N-Butyl-2-Cyanoacrylate Skin Adhesive Glue Versus Standard Ethilon Suture for Skin Closure of Clean Wounds in a Tertiary Care Setting
International Journal of Drug Delivery Technology · 20.04.2026 · 16 (14s)
DOI: 10.25258/ijddt.16.14s.59 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 20.04.2026. Verfasst von Sreearthi R und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
Optimal closure of clean skin wounds should provide effective treatment, cosmetic benefit, and comfort to the patient. This study compared the efficacy of the tissue adhesive (N-butyl-2-cyanoacrylate) to that of standard Ethilon sutures.
Methods
A prospective, randomized comparative study was performed using an equal number of subjects (50) divided into two groups (Group A) and (Group B). All outcomes measured were based on a combination of ratings for procedure time, Visual Analog Scale (VAS) for pain reported by the patient, healing of wounds at three months through the Vancouver Scar Scale (VSS) rating system, complication rates, and satisfaction ratings.
Results
Results showed that the amount of time needed to complete the procedure was significantly less for the adhesive group (3.8 ± 1.1 minutes) than for the Ethilon suture group (12.5 ± 2.9 minutes) with a P-value of less than 0.001; the amount of pain experienced immediately after the procedure was less for the adhesive group (VAS score of 1.6 ± 0.8) than for the Ethilon suture group (VAS score of 3.4 ± 1.2) with a P-value of less than 0.001; and that the rate of complications (8% for the adhesive group versus 16% for the Ethilon suture group, P-value = 0.387) and three-month VSS scores (2.6 ± 1.8 for the adhesive group versus 3.3 ± 2.1 for the Ethilon suture group, P-value = 0.191) were similar across the two groups.
Conclusion
Patient satisfaction was higher in the adhesive group than in the Ethilon suture group with 72% of patients reporting that they were "very satisfied" with the adhesive and only 40% reporting that they were "very satisfied" with the Ethilon suture method; the P-value was equal to 0.038
Zitieren
APA
R, S., Raj, F. A., & S, M. (2026). A Comparative Study Between N-Butyl-2-Cyanoacrylate Skin Adhesive Glue Versus Standard Ethilon Suture for Skin Closure of Clean Wounds in a Tertiary Care Setting. International Journal of Drug Delivery Technology, 16(14s). https://doi.org/10.25258/ijddt.16.14s.59
Vancouver
R S, Raj FA, S M. A Comparative Study Between N-Butyl-2-Cyanoacrylate Skin Adhesive Glue Versus Standard Ethilon Suture for Skin Closure of Clean Wounds in a Tertiary Care Setting. International Journal of Drug Delivery Technology. 2026;16(14s). doi:10.25258/ijddt.16.14s.59
BibTeX
@article{R2026,
author = {R, Sreearthi and Raj, Felix Anand and S, Manibalan},
title = {A Comparative Study Between N-Butyl-2-Cyanoacrylate Skin Adhesive Glue Versus Standard Ethilon Suture for Skin Closure of Clean Wounds in a Tertiary Care Setting},