EUVIMEDEUVIMED entdecken
Crossref

Ultrasonographic Evaluation of Fetal Biometric ParametersforGestational Age Estimation in Second Trimester Pregnancy: ACross-Sectional Study

Bharati Ghotane, Archana V Salunkhe, Prafulla Dakhane, Priya Patil, Vasudha Nikam

International Journal of Drug Delivery Technology · 21.04.2026 · 16 (10s)

DOI: 10.25258/ijddt.16.10s.62 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Drug Delivery Technology, online erschienen am 21.04.2026. Verfasst von Bharati Ghotane und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background: roper estimation of gestational age is crucial in the process of effective prenatal care andobstetric control. Ultrasonography is a good method of measuring fetal biometrics in order to estimate the gestational age of a pregnancy.

Objective

To determine reference values of the fetal biometric measurements of biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL) during the secondtrimester and determine the relationship between these variables and gestational age. Materials and Methods: 350 healthy pregnant women aged 14-27 weeks of gestation that were visiting the Department of Radiology were studied in a cross-sectional study. Measurement of BPD, HC, AC, and FLwas carried out with the help of real-time ultrasonography through the usage of linear array transducer. Women pregnant more than once, with illnesses in the maternal tract, doubtful last menstrual period, or fetal anomalies were excluded. Statistical analysis involved determination of mean, standard deviation, correlation and unpaired t -test.

Results

All the four biometric parameters depicted a linear increase with the increasing gestational age. The results of BPD varied between 23-73 mm (mean: 50.91+38.26 mm), FL between 10-53 mm(mean: 34.05+12.06 mm), AC between 62-229 mm(mean: 152.27+51.8 mm) and HC between 82-268 mm(mean: 179.51+51.8 mm). The BPD-HC (r=0.4), BPD-AC (r=0.41), BPD-FL (r=0.405), HC-AC (r=0.925), HC-FL(r=0.949), and AC-FL (r=0.957) were found to be strongly positively correlated with each other. All the correlations were significant (p

Zitieren

APA

Ghotane, B., Salunkhe, A. V., Dakhane, P., Patil, P., & Nikam, V. (2026). Ultrasonographic Evaluation of Fetal Biometric ParametersforGestational Age Estimation in Second Trimester Pregnancy: ACross-Sectional Study. International Journal of Drug Delivery Technology, 16(10s). https://doi.org/10.25258/ijddt.16.10s.62

Vancouver

Ghotane B, Salunkhe AV, Dakhane P, Patil P, Nikam V. Ultrasonographic Evaluation of Fetal Biometric ParametersforGestational Age Estimation in Second Trimester Pregnancy: ACross-Sectional Study. International Journal of Drug Delivery Technology. 2026;16(10s). doi:10.25258/ijddt.16.10s.62

BibTeX
@article{Ghotane2026,
  author = {Ghotane, Bharati and Salunkhe, Archana V and Dakhane, Prafulla and Patil, Priya and Nikam, Vasudha},
  title = {Ultrasonographic Evaluation of Fetal Biometric ParametersforGestational Age Estimation in Second Trimester Pregnancy: ACross-Sectional Study},
  journal = {International Journal of Drug Delivery Technology},
  year = {2026},
  volume = {16},
  number = {10s},
  doi = {10.25258/ijddt.16.10s.62}
}
Kostenlos starten →