EUVIMEDEUVIMED entdecken
Crossref

A Study of Association between Maternal Vitamin D Levels with Neonatal Anthropometry and Clinical Outcome in a Rural Tertiary Care Center

Sayan Das, Subhajit Dutta, Deeya Paul

International Journal of Current Pharmaceutical Review and Research · 30.07.2026 · 18 (07)

DOI: 10.25258/ijcpr.18.7.81 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Current Pharmaceutical Review and Research, online erschienen am 30.07.2026. Verfasst von Sayan Das und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Maternal vitamin D plays an important role in fetal growth and neonatal health. Its association with neonatal anthropometry and clinical outcome remains uncertain. This study evaluated maternal vitamin D status and its relationship with neonatal vitamin D level, anthropometric measurements, and neonatal outcome.

Methods

This hospital-based prospective observational study included 90 pregnant women and their newborns delivered at a tertiary care hospital in Rajasthan between April 2021 and March 2022. Maternal and neonatal serum vitamin D levels were measured using chemiluminescence immunoassay. Maternal background characteristics, gestational age, birth weight, neonatal anthropometry, NICU admission, and neonatal outcome were recorded. Statistical analysis included Chi-square test, Pearson correlation, and receiver operating characteristic (ROC) analysis.

Results

The mean maternal and neonatal vitamin D levels were 36.60 ± 13.96 ng/mL and 39.07 ± 13.70 ng/mL, respectively. Maternal vitamin D was sufficient in 74.44% of mothers, 85.56% of newborns had normal vitamin D levels. Maternal vitamin D status was not significantly associated with maternal background characteristics, gestational age, and birth weight, weight for gestational age, neonatal length, head circumference, NICU admission, or neonatal outcome (all p > 0.05). Very strong positive correlation was observed between maternal and neonatal vitamin D levels (r = 0.95, p < 0.001). Maternal vitamin D cut-off of >17.5 ng/mL predicted normal neonatal vitamin D status with 98.75% sensitivity, 100.00% specificity, and 98.89% diagnostic accuracy.

Conclusion

Maternal vitamin D level was strongly associated with neonatal vitamin D level and accurately predicted neonatal vitamin D status. No significant association was found between maternal vitamin D status and neonatal anthropometry or short-term neonatal outcome in this study.

Zitieren

APA

Das, S., Dutta, S., & Paul, D. (2026). A Study of Association between Maternal Vitamin D Levels with Neonatal Anthropometry and Clinical Outcome in a Rural Tertiary Care Center. International Journal of Current Pharmaceutical Review and Research, 18(07). https://doi.org/10.25258/ijcpr.18.7.81

Vancouver

Das S, Dutta S, Paul D. A Study of Association between Maternal Vitamin D Levels with Neonatal Anthropometry and Clinical Outcome in a Rural Tertiary Care Center. International Journal of Current Pharmaceutical Review and Research. 2026;18(07). doi:10.25258/ijcpr.18.7.81

BibTeX
@article{Das2026,
  author = {Das, Sayan and Dutta, Subhajit and Paul, Deeya},
  title = {A Study of Association between Maternal Vitamin D Levels with Neonatal Anthropometry and Clinical Outcome in a Rural Tertiary Care Center},
  journal = {International Journal of Current Pharmaceutical Review and Research},
  year = {2026},
  volume = {18},
  number = {07},
  doi = {10.25258/ijcpr.18.7.81}
}
Kostenlos starten →