EUVIMEDEUVIMED entdecken
Crossref

Revisiting Forced Expiratory Time: Prospective Validation of a Simple Bedside Test for Airway Obstruction

Ravi Bairwa, Mani Tiwari, Vishesh Mohan Saxena, Kartik Mishra

International Journal of Current Pharmaceutical Review and Research · 30.07.2026 · 18 (07)

DOI: 10.25258/ijcpr.18.7.144 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Current Pharmaceutical Review and Research, online erschienen am 30.07.2026. Verfasst von Ravi Bairwa und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Chronic obstructive pulmonary disease (COPD) and bronchial asthma remain leading causes of respiratory morbidity and mortality worldwide. Despite effective treatment options, a large proportion of patients in low- and middle-income countries remain undiagnosed because spirometry—the reference standard for diagnosing airflow obstruction—is often unavailable outside specialised centres. Forced expiratory time (FET), measured with a stethoscope and stopwatch, offers a simple bedside alternative, but contemporary prospective validation data from South Asian populations remain limited.

Objectives

To evaluate the diagnostic accuracy of auscultated FET for detecting spirometry-confirmed airway obstruction, determine an optimal diagnostic threshold, and assess its feasibility and patient acceptability in routine outpatient practice.

Methods

We conducted a prospective cross-sectional diagnostic accuracy study in consecutive symptomatic adults attending a tertiary care teaching hospital in North India between June 2024 and June 2025. Participants underwent standardised FET measurement followed by spirometry performed according to American Thoracic Society/European Respiratory Society recommendations. Airway obstruction was defined as a postbronchodilator FEV₁/FVC ratio 6.0 seconds, sensitivity was 86.5% (95% CI 74.2–94.4), specificity 79.6% (95% CI 65.7–89.8), positive predictive value 81.8%, negative predictive value 84.8%, and overall diagnostic accuracy 83.2%. The positive and negative likelihood ratios were 4.24 and 0.17, respectively, with an AUC of 0.92. Mean FET increased progressively with disease severity, from 7.2 ± 0.7 seconds in mild obstruction to 9.1 ± 0.9 seconds in severe obstruction. FET took substantially less time to perform than spirometry (2.0 vs. 8.0 minutes) and was associated with higher patient acceptability.

Conclusions

Auscultated FET demonstrated good diagnostic performance as an initial screening test for airflow obstruction, particularly for excluding disease when spirometry is unavailable. Its simplicity, minimal equipment requirements, rapid administration, and favourable patient acceptance make it an attractive triage tool for primary care and resource-constrained healthcare settings. Larger multicentre studies are warranted to establish its role within contemporary respiratory screening pathways.

Zitieren

APA

Bairwa, R., Tiwari, M., Saxena, V. M., & Mishra, K. (2026). Revisiting Forced Expiratory Time: Prospective Validation of a Simple Bedside Test for Airway Obstruction. International Journal of Current Pharmaceutical Review and Research, 18(07). https://doi.org/10.25258/ijcpr.18.7.144

Vancouver

Bairwa R, Tiwari M, Saxena VM, Mishra K. Revisiting Forced Expiratory Time: Prospective Validation of a Simple Bedside Test for Airway Obstruction. International Journal of Current Pharmaceutical Review and Research. 2026;18(07). doi:10.25258/ijcpr.18.7.144

BibTeX
@article{Bairwa2026,
  author = {Bairwa, Ravi and Tiwari, Mani and Saxena, Vishesh Mohan and Mishra, Kartik},
  title = {Revisiting Forced Expiratory Time: Prospective Validation of a Simple Bedside Test for Airway Obstruction},
  journal = {International Journal of Current Pharmaceutical Review and Research},
  year = {2026},
  volume = {18},
  number = {07},
  doi = {10.25258/ijcpr.18.7.144}
}
Kostenlos starten →