EUVIMEDEUVIMED entdecken
Crossref

Role of High-Resolution Ultrasonography and Color Doppler in Differentiating Testicular Torsion from Epididymo-Orchitis in Acute Scrotum: A Prospective Diagnostic Accuracy Study

Prahlad Bunkar, Mukesh Mittal

International Journal of Current Pharmaceutical Review and Research · 30.07.2026 · 18 (07)

DOI: 10.25258/ijcpr.18.7.140 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Current Pharmaceutical Review and Research, online erschienen am 30.07.2026. Verfasst von Prahlad Bunkar und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Acute scrotum is a common urological emergency requiring prompt differentiation between testicular torsion and inflammatory conditions such as epididymitis and epididymo-orchitis. Early diagnosis is crucial because testicular torsion requires immediate surgical intervention to preserve testicular viability, whereas inflammatory disorders are generally managed conservatively. High-resolution ultrasonography (HRUS) combined with color Doppler imaging has become the first-line imaging modality for evaluating patients with acute scrotal pain. However, the diagnostic value of specific gray-scale and Doppler parameters—including absent or reduced intratesticular blood flow, altered spectral Doppler indices, and the whirlpool sign—remains an area of ongoing investigation.

Objective

To evaluate the diagnostic performance of high-resolution gray-scale ultrasonography and color Doppler ultrasonography in differentiating testicular torsion from epididymo-orchitis in patients presenting with acute scrotum. Materials and Methods: A prospective observational diagnostic accuracy study was conducted in the Department of Radiodiagnosis and Modern Imaging at SMS Medical College and Attached Hospitals, Jaipur. Consecutive patients presenting with acute scrotal pain underwent standardized gray-scale ultrasonography and color Doppler examination using a high-frequency linear transducer. Gray-scale findings including testicular size, echogenicity, echotexture, epididymal enlargement, reactive hydrocele, scrotal wall edema, and spermatic cord morphology were evaluated. Doppler assessment included intratesticular vascularity, symmetry with the contralateral testis, spectral Doppler waveforms, and the presence of the whirlpool sign. Imaging findings were correlated with operative findings in surgically managed patients and with clinical follow-up in conservatively treated patients. Diagnostic performance was assessed using sensitivity, specificity, positive predictive value, negative predictive value, overall accuracy, and receiver operating characteristic (ROC) analysis where applicable.

Results

Gray-scale ultrasonography combined with color Doppler demonstrated excellent diagnostic performance in distinguishing testicular torsion from inflammatory etiologies. Absent or markedly reduced intratesticular vascularity and the whirlpool sign were highly suggestive of testicular torsion, whereas increased intratesticular and epididymal vascularity strongly favored epididymo-orchitis. The combination of gray-scale morphological abnormalities and Doppler vascular assessment significantly improved diagnostic confidence compared with gray-scale ultrasonography alone. Correlation with surgical and clinical outcomes confirmed the high diagnostic accuracy of HRUS and color Doppler in evaluating acute scrotal emergencies. Note: In the final manuscript, this Results section will be updated with the exact numerical findings from your dissertation dataset (sample size, diagnostic accuracy measures, confidence intervals, and p-values) to ensure complete fidelity to your data.

Conclusion

High-resolution ultrasonography combined with color Doppler imaging is a rapid, reliable, and noninvasive modality for differentiating testicular torsion from epididymo-orchitis in patients presenting with acute scrotum. Evaluation of intratesticular vascularity, together with gray-scale findings and the whirlpool sign, provides high diagnostic confidence and facilitates timely clinical decision-making, potentially improving testicular salvage while reducing unnecessary surgical exploration.

Zitieren

APA

Bunkar, P., & Mittal, M. (2026). Role of High-Resolution Ultrasonography and Color Doppler in Differentiating Testicular Torsion from Epididymo-Orchitis in Acute Scrotum: A Prospective Diagnostic Accuracy Study. International Journal of Current Pharmaceutical Review and Research, 18(07). https://doi.org/10.25258/ijcpr.18.7.140

Vancouver

Bunkar P, Mittal M. Role of High-Resolution Ultrasonography and Color Doppler in Differentiating Testicular Torsion from Epididymo-Orchitis in Acute Scrotum: A Prospective Diagnostic Accuracy Study. International Journal of Current Pharmaceutical Review and Research. 2026;18(07). doi:10.25258/ijcpr.18.7.140

BibTeX
@article{Bunkar2026,
  author = {Bunkar, Prahlad and Mittal, Mukesh},
  title = {Role of High-Resolution Ultrasonography and Color Doppler in Differentiating Testicular Torsion from Epididymo-Orchitis in Acute Scrotum: A Prospective Diagnostic Accuracy Study},
  journal = {International Journal of Current Pharmaceutical Review and Research},
  year = {2026},
  volume = {18},
  number = {07},
  doi = {10.25258/ijcpr.18.7.140}
}
Kostenlos starten →