Introduction

The uncertainty tool has an important role for evaluation of analytical performance in any clinical laboratory. For having the quality of the analytical performance & planning the strategy of quality control, sigma metrics and QGI ratio are used as an uncertainty measurement tools. The study was done to estimate the analytical performance of clinical biochemistry laboratory of College of Medicine & Sagore Dutta Hospital by calculating Sigma metrics and QGI ratio. Methodology: the study was done in the Department of Biochemistry, College of Medicine and Sagore Dutta Hospital. The past 6 months’ (September 2025 to February 2026) of internal Quality Control reports of daily QC run as a part of routine analytical and maintenance performance of autoanalyzer ERBA XL 640 of routine parameters were analysed. The common Laboratory Parameters were used Blood glucose, Urea, Creatinine, Cholesterol, Triglyceride, HDL, LDL, ALP, SGPT, SGOT, Total Protein, Albumin, Total Bilirubin and Direct Bilirubin.

Result

The sigma levels of Level 1 the values of urea, creatinine, ALP and total protein are having their sigma levels in between 3 and 4. Sigma level L2 the value of total bilirubin is also is below 3 (2.99Ϭ) indicating unacceptable performance. Which can be considered as marginal performance and needs to improve the performance to maintain the quality. According to the Quality goal indicator values of these marginal and unacceptable performances indicate the possibilities of random errors.

Zitieren

APA

S, C., S, S., A, G., & S, G. (2026). Quantification of Uncertainty of Common Laboratory Parameters in a Clinical Laboratory in a Tertiary Care Institute. International Journal of Current Pharmaceutical Review and Research, 18(06). https://doi.org/10.25258/ijcpr.18.6.142

Vancouver

S C, S S, A G, S G. Quantification of Uncertainty of Common Laboratory Parameters in a Clinical Laboratory in a Tertiary Care Institute. International Journal of Current Pharmaceutical Review and Research. 2026;18(06). doi:10.25258/ijcpr.18.6.142

BibTeX
@article{S2026,
  author = {S, Chatterjee and S, Sinha and A, Ghosh and S, Ghosh},
  title = {Quantification of Uncertainty of Common Laboratory Parameters in a Clinical Laboratory in a Tertiary Care Institute},
  journal = {International Journal of Current Pharmaceutical Review and Research},
  year = {2026},
  volume = {18},
  number = {06},
  doi = {10.25258/ijcpr.18.6.142}
}
Kostenlos starten →