EUVIMEDEUVIMED entdecken
Crossref

Comparative evaluation of hemodynamic responses to laryngoscopy and endotracheal intubation using Macintosh, McCoy, and C-MAC laryngoscopes in adult patients undergoing general anaesthesia

CKV Sirisha, Padmalatha Seelam, Zohra Mehdi

International Journal of Current Pharmaceutical Review and Research · 11.03.2026 · 18 (03)

DOI: 10.25258/ijcpr.18.3.51 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Current Pharmaceutical Review and Research, online erschienen am 11.03.2026. Verfasst von CKV Sirisha und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Laryngoscopy and endotracheal intubation provoke significant hemodynamic changes due to sympathetic stimulation. Various laryngoscopes, such as Macintosh, McCoy, and C-MAC, differ in design and degree of glottic stimulation, influencing cardiovascular responses.

Aim

To compare the hemodynamic responses to laryngoscopy and intubation using Macintosh, McCoy, and CMAC laryngoscopes in adult patients undergoing elective surgeries under general anaesthesia.

Methods

This randomized, single-blinded study was conducted on 120 ASA I–II adults (aged 18–60 years) undergoing elective surgeries at GSL Medical College, Andhra Pradesh. Participants were divided into three groups (n=40 each): Group A – Macintosh, Group B – McCoy, and Group C – C-MAC. Standard induction agents were used, and hemodynamic parameters heart rate, systolic blood pressure, diastolic blood pressure, and mean arterial pressure were recorded at baseline, before intubation, and 1, 3, 5, and 10 minutes after intubation. Data were analyzed using SPSS v21.0; p < 0.05 was considered significant.

Results

All groups showed transient hemodynamic increases post-intubation, most pronounced with Macintosh and least with C-MAC. The McCoy group demonstrated intermediate values. C-MAC produced significantly lower rises in heart rate and blood pressure (p < 0.001).

Conclusion

C-MAC video laryngoscope provides superior hemodynamic stability compared with Macintosh and McCoy laryngoscopes during intubation.

Zitieren

APA

Sirisha, C., Seelam, P., & Mehdi, Z. (2026). Comparative evaluation of hemodynamic responses to laryngoscopy and endotracheal intubation using Macintosh, McCoy, and C-MAC laryngoscopes in adult patients undergoing general anaesthesia. International Journal of Current Pharmaceutical Review and Research, 18(03). https://doi.org/10.25258/ijcpr.18.3.51

Vancouver

Sirisha C, Seelam P, Mehdi Z. Comparative evaluation of hemodynamic responses to laryngoscopy and endotracheal intubation using Macintosh, McCoy, and C-MAC laryngoscopes in adult patients undergoing general anaesthesia. International Journal of Current Pharmaceutical Review and Research. 2026;18(03). doi:10.25258/ijcpr.18.3.51

BibTeX
@article{Sirisha2026,
  author = {Sirisha, CKV and Seelam, Padmalatha and Mehdi, Zohra},
  title = {Comparative evaluation of hemodynamic responses to laryngoscopy and endotracheal intubation using Macintosh, McCoy, and C-MAC laryngoscopes in adult patients undergoing general anaesthesia},
  journal = {International Journal of Current Pharmaceutical Review and Research},
  year = {2026},
  volume = {18},
  number = {03},
  doi = {10.25258/ijcpr.18.3.51}
}
Kostenlos starten →