EUVIMEDEUVIMED entdecken
Crossref

Estimating length to place central venous catheter tip at mid-superior vena cava

Sameh M. Hakim, Hanaa A. Elgendy, Doaa M. Kamal El-Din, Mohamed M. Rashed, Ghada R. Elgiushy, Mohamed O. Elgouhary

Revista Chilena de Anestesia · 2026

DOI: 10.25237/revchilanestv55n2-08 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista Chilena de Anestesia, 2026. Verfasst von Sameh M. Hakim und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to derive a prediction rule for estimating the required length to place the tip of a right internal jugular vein (IJV) catheter at the mid-point of the superior vena cava using surface landmarks.

Methods

The distance from the apex of Sedillot’s triangle to the ipsilateral sternoclavicular joint and from the latter to the lower border of the right second sternocostal junction was summed and regressed on the actual length required to place the catheter tip at 30 mm cephalad to the atrio-caval junction as determined with transesophageal echocardiography (TEE) in 70 adults undergoing right IJV catheterization. The accuracy of the proposed rule was evaluated by calculation of the standard error of the estimate (SEest) and was compared with Peres’ formula and the C-length methods.

Results

The proposed rule had a SEest of 8.4 mm compared with 14.0 mm and 30.7 mm for the C-length and Peres’ formula, respectively. The standardized mean difference (95% confidence interval) between the catheter length predicted with the surface landmarks rule and that estimated with TEE was 0.00 (-0.24, 0.24), P > .999. The corresponding difference from the TEE estimations was -0.36 (-0.61, -0.12), P = .003 and 2.42 (2.02, 2.82), P < .0001, for the C-length and Peres’ formula, respectively. K-fold cross-validation of the proposed rule showed a mean cross-validation score of 0.135 mm.

Conclusion

The proposed surface landmarks rule has a high accuracy that is comparable to TEE and performs better than Peres’ formula or the C-length method. External validation of the rule is required.

Zitieren

APA

Hakim, S. M., Elgendy, H. A., El-Din, D. M. K., Rashed, M. M., Elgiushy, G. R., & Elgouhary, M. O. (2026). Estimating length to place central venous catheter tip at mid-superior vena cava. Revista Chilena de Anestesia. https://doi.org/10.25237/revchilanestv55n2-08

Vancouver

Hakim SM, Elgendy HA, El-Din DMK, Rashed MM, Elgiushy GR, Elgouhary MO. Estimating length to place central venous catheter tip at mid-superior vena cava. Revista Chilena de Anestesia. 2026. doi:10.25237/revchilanestv55n2-08

BibTeX
@article{Hakim2026,
  author = {Hakim, Sameh M. and Elgendy, Hanaa A. and El-Din, Doaa M. Kamal and Rashed, Mohamed M. and Elgiushy, Ghada R. and Elgouhary, Mohamed O.},
  title = {Estimating length to place central venous catheter tip at mid-superior vena cava},
  journal = {Revista Chilena de Anestesia},
  year = {2026},
  doi = {10.25237/revchilanestv55n2-08}
}
Kostenlos starten →