EUVIMEDEUVIMED entdecken
Crossref

Ultrasound Imaging of Lumbar Multifidus Morphology and Quality – A Prospective Study on Monitoring Acute Adaptations to Specific Exercise and on Reliability

Bruno Domokos, Lea Dauber, Holger Reimers, Gustav Andersson, Florian Alfen, Christoph Raschka, Christoph Spang

JOSPT Open · 2024-10 · 2 (4) · 354-363

DOI: 10.2519/josptopen.2024.0253 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JOSPT Open, 2024-10. Verfasst von Bruno Domokos und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To test the reliability of a rehabilitative ultrasound imaging (RUSI) protocol for analyzing lumbar multifidus morphologic characteristics for use by clinicians, and to analyze the specificity of isolated lumbar extension resistance exercise (ILEX) DESIGN: Intrarater reliability and interrater (imaging and quantification) reliability. METHODS: A standardized RUSI protocol was developed and the reliability of the procedure and image analysis (intraclass correlations coefficient [ICC], standard error of the measurement [SEM], minimum detectable change [MDC%]) was analyzed. Lumbar multifidus RUSI measures of muscles thickness, cross-sectional area, and echogenicity were obtained before and after 1 ILEX set with uniform time under tension and range of motion (12°-42°). RESULTS: Intrarater (between-day) reliability was similar (ICC, 0.88-0.97; SEM, 0.14-5.08; MDC%: 11-20) compared to interrater (same day) imaging reliability (ICC, 0.91-0.99; SEM, 0.09-3.78; MDC%, 8-15) and interrater quantification reliability (ICC, 0.83-0.97; SEM, 0.07-2.80; MDC%: 6-25). There was a significant increase of lumbar multifidus muscle thickness (pre-ILEX, 2.94 cm; post-ILEX, 3.16 cm; P

Zitieren

APA

Domokos, B., Dauber, L., Reimers, H., Andersson, G., Alfen, F., Raschka, C., & Spang, C. (2024). Ultrasound Imaging of Lumbar Multifidus Morphology and Quality – A Prospective Study on Monitoring Acute Adaptations to Specific Exercise and on Reliability. JOSPT Open, 2(4), 354-363. https://doi.org/10.2519/josptopen.2024.0253

Vancouver

Domokos B, Dauber L, Reimers H, Andersson G, Alfen F, Raschka C, et al. Ultrasound Imaging of Lumbar Multifidus Morphology and Quality – A Prospective Study on Monitoring Acute Adaptations to Specific Exercise and on Reliability. JOSPT Open. 2024;2(4):354-363. doi:10.2519/josptopen.2024.0253

BibTeX
@article{Domokos2024,
  author = {Domokos, Bruno and Dauber, Lea and Reimers, Holger and Andersson, Gustav and Alfen, Florian and Raschka, Christoph and Spang, Christoph},
  title = {Ultrasound Imaging of Lumbar Multifidus Morphology and Quality – A Prospective Study on Monitoring Acute Adaptations to Specific Exercise and on Reliability},
  journal = {JOSPT Open},
  year = {2024},
  volume = {2},
  number = {4},
  pages = {354--363},
  doi = {10.2519/josptopen.2024.0253}
}
Kostenlos starten →