Penerapan Metode Reverse Engineering untuk Penggantian Preheater Fan 4J1P05 di Pabrik Indarung IV PT Semen Padang
Jurnal Praktik Keinsinyuran · 30.05.2025 · 2 (2) · 148-160
DOI: 10.25170/jpk.v2i2.6356 ↗Kurz gefasst
Fachartikel in der Zeitschrift Jurnal Praktik Keinsinyuran, online erschienen am 30.05.2025. Verfasst von Muhammad Fadel und 2 weiteren Autor:innen.
Abstract (Originalsprache)
This paper describes the replacement of the centrifugal induced draft (ID) fan on the 4J1P05 Preheater Fan at the Indarung IV Kiln, PT Semen Padang using the reverse engineering method and remanufacturing it locally. The 4J1P05 Preheater Fan is a large fan with a diameter of 3025 mm with the ability to operate at high temperatures (350°C – 450°C). After more than 25 years of use, the fan experienced high wear on the impeller which caused unbalance on the impeller resulting in high vibrations when operating. Therefore, it was planned to replace the fan immediately but there was a problem with the safety of purchasing. The procurement process for imported goods took 12 months. PT Semen Padang carried out reverse engineering and remanufacturing fan impellers by utilizing local resources. The 4J1P05 Fan Preheater was successfully manufactured, installed and tested and operates normally again.
Zitieren
APA
Fadel, M., Sutanto, H., & Yanto (2025). Penerapan Metode Reverse Engineering untuk Penggantian Preheater Fan 4J1P05 di Pabrik Indarung IV PT Semen Padang. Jurnal Praktik Keinsinyuran, 2(2), 148-160. https://doi.org/10.25170/jpk.v2i2.6356
Vancouver
Fadel M, Sutanto H, Yanto. Penerapan Metode Reverse Engineering untuk Penggantian Preheater Fan 4J1P05 di Pabrik Indarung IV PT Semen Padang. Jurnal Praktik Keinsinyuran. 2025;2(2):148-160. doi:10.25170/jpk.v2i2.6356
BibTeX
@article{Fadel2025,
author = {Fadel, Muhammad and Sutanto, Hadi and Yanto},
title = {Penerapan Metode Reverse Engineering untuk Penggantian Preheater Fan 4J1P05 di Pabrik Indarung IV PT Semen Padang},
journal = {Jurnal Praktik Keinsinyuran},
year = {2025},
volume = {2},
number = {2},
pages = {148--160},
doi = {10.25170/jpk.v2i2.6356}
}
EUVIMED