Enhanced battery energy storage damping controller for alleviation sub-synchronous resonance in wind power plants
Science and Technology for Energy Transition · 2026 · 81 · 18
DOI: 10.2516/stet/2026032 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science and Technology for Energy Transition, online erschienen am 22.07.2026. Verfasst von Neevatika Verma und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The study introduces an enhanced damping controller using a battery energy storage system to mitigate sub-synchronous resonance in transmission lines equipped with static series compensation associated with a doubly fed induction generator-based wind power facility. This project aims to create a resilient damping controller that ensures stability under diverse operating situations and to refine controller settings using an innovative optimization technique for enhanced damping efficacy. In contrast to traditional damping controllers, the suggested controller incorporates an additional damping signal integrated into the d – q axis of the control channels. The auxiliary damping signal utilizes angular speed deviation, obtained by a large-area measuring method, as its input signal. A hybrid method integrating eigenvalue analysis with an advanced particle swarm optimization technique is used to optimize damping performance across diverse operating situations by determining the best gain coefficients. The variability of wind speed and fluctuations in series compensation levels are assessed to determine the resilience of thef proposed controller in real-world and extreme circumstances. Time-domain simulations were conducted in MATLAB/Simulink to assess their efficacy. The findings confirm that the proposed upgraded controller successfully stabilizes all previously unstable system modes at wind speeds of 7 m/s, 9 m/s, and 11 m/s, as well as at compensation levels of 40%, 55%, and 60%. The suggested controller demonstrates enhanced damping performance and elevated damping coefficients relative to conventional damping controllers, signifying increased stability and resilience across various operating conditions.
Zitieren
APA
Verma, N., Kumar, N., & Kumar, R. (2026). Enhanced battery energy storage damping controller for alleviation sub-synchronous resonance in wind power plants. Science and Technology for Energy Transition, 81, 18. https://doi.org/10.2516/stet/2026032
Vancouver
Verma N, Kumar N, Kumar R. Enhanced battery energy storage damping controller for alleviation sub-synchronous resonance in wind power plants. Science and Technology for Energy Transition. 2026;81:18. doi:10.2516/stet/2026032
BibTeX
@article{Verma2026,
author = {Verma, Neevatika and Kumar, Narendra and Kumar, Rajeev},
title = {Enhanced battery energy storage damping controller for alleviation sub-synchronous resonance in wind power plants},
journal = {Science and Technology for Energy Transition},
year = {2026},
volume = {81},
pages = {18},
doi = {10.2516/stet/2026032}
}
EUVIMED