EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Numerical Investigation of the Effect of Post Notching Size and Location on the Behavior of Reinforced Concrete Beam before and after Strengthening

Harith Al-Salman, Hassanin Abd Ali Alfatlawy, Zainb Kareem Al-Mamory, Hayder Abdulwahid Khalaf, Fuad Abutaha

Tikrit Journal of Engineering Sciences · 06.05.2026 · 33 (1) · 1-17

DOI: 10.25130/tjes.33.1.12 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tikrit Journal of Engineering Sciences, online erschienen am 06.05.2026. Verfasst von Harith Al-Salman und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Some structural concrete projects suffered from post-casting changes or modifications to accommodate pipe services due to inefficient initial planning or management. This study aims to evaluate the performance of a reinforced concrete beam with dimensions of 300 mm x 600 mm x 3800 mm for width, height, and span length, respectively. Notches were made at various locations on the face of the support, with various notch depths. A nonlinear parametric three-dimensional (3D) finite element model was developed in Abaqus to evaluate the structural behavior of models subjected to notching with a fixed width of about 150 mm and a length equal to the beam width (or 300 mm). The study covered two main parameters: notch locations at three distances from the face of support (1d,2d, and 3d), and notch depth (0.5d and 0.75 d). Several parameters were adopted as evaluation criteria, including maximum load-carrying capacity, stiffness, ductility, and toughness. Results revealed that the most critical location occurs when the notch distance is three times the beam's clear span, compared to other cases. Also, a notch depth of 0.75d in some locations has a slight effect compared with a notch depth of 0.5d. A steel strip jacket was introduced as an enhancement modification, with a specific configuration for all studied parameters, and showed comparable efficiency to the unnotched beam model.

Zitieren

APA

Al-Salman, H., Alfatlawy, H. A. A., Al-Mamory, Z. K., Khalaf, H. A., & Abutaha, F. (2026). Numerical Investigation of the Effect of Post Notching Size and Location on the Behavior of Reinforced Concrete Beam before and after Strengthening. Tikrit Journal of Engineering Sciences, 33(1), 1-17. https://doi.org/10.25130/tjes.33.1.12

Vancouver

Al-Salman H, Alfatlawy HAA, Al-Mamory ZK, Khalaf HA, Abutaha F. Numerical Investigation of the Effect of Post Notching Size and Location on the Behavior of Reinforced Concrete Beam before and after Strengthening. Tikrit Journal of Engineering Sciences. 2026;33(1):1-17. doi:10.25130/tjes.33.1.12

BibTeX
@article{AlSalman2026,
  author = {Al-Salman, Harith and Alfatlawy, Hassanin Abd Ali and Al-Mamory, Zainb Kareem and Khalaf, Hayder Abdulwahid and Abutaha, Fuad},
  title = {Numerical Investigation of the Effect of Post Notching Size and Location on the Behavior of Reinforced Concrete Beam before and after Strengthening},
  journal = {Tikrit Journal of Engineering Sciences},
  year = {2026},
  volume = {33},
  number = {1},
  pages = {1--17},
  doi = {10.25130/tjes.33.1.12}
}