Abstract (Originalsprache)

Accurate measurement of corneal endothelial cell density (ECD) is crucial in evaluating the viability of donor corneas for transplantation. The consistency of ECD measurements is critical for predicting post-transplant results and monitoring corneal health. However, measurement methods have evolved, moving from manual counting to more complex semi-automatic and fully automated systems, including AI-powered solutions. This study compares the accuracy, dependability, and efficiency of manual, semi-automated, and fully automated ECD measurement techniques. It investigates the degree of heterogeneity among techniques and evaluates their potential to improve clinical outcomes in corneal transplantation. The sample includes corneal data from 300 participants, 150 male and 150 female donors, who were divided into three groups based on the measurement method: manual, semi-automated, or fully automated. The study also examined the gender distribution to see whether there was any difference in results between male and female donor corneas. Manual counting has previously been notable for its variability due to operator expertise and calibration discrepancies, with mean ECD values ranging from 2146 to 2775 cells/mm² (p < 0.05). Semi-automated procedures, which combine manual input with software aid, enhance consistency. In the Cornea Preservation Time Study, eye banks reported a mean ECD of 2773 ± 300 cells/mm², while CIARC reported 2758 ± 388 cells/mm², with agreement limits ranging from [-644, 675] cells/mm² (p < 0.05). The AxoNet deep learning model had a mean absolute error (MAE) of 12.1 cells/mm² and an R² value of 0.948, making it the most accurate fully automated system. A separate study on AI-based detection of aberrant endothelium cells achieved an accuracy of 0.95, precision of 0.92, recall of 0.94, and F1 score of 0.93, and an AUC-ROC of 0.98 (p < 0.01). Fully automated AI-based methods surpass manual and semi-automated approaches in accuracy and consistency, significantly reducing time and labor. The findings highlight the importance of adopting AI-driven technologies to enhance diagnostic precision and efficiency in clinical settings. However, the need for standardized calibration procedures and high- quality image acquisition remains critical for reliable ECD measurement.

Zitieren

APA

Obi, M. F., Schweitzer, S., & Goswami, T. (2025). A Data-Driven Evaluation of ECD Measurement Techniques Across Traditional and AI-Based Modalities. Research on Intelligent Manufacturing and Assembly. https://doi.org/10.25082/rima.2025.02.002

Vancouver

Obi MF, Schweitzer S, Goswami T. A Data-Driven Evaluation of ECD Measurement Techniques Across Traditional and AI-Based Modalities. Research on Intelligent Manufacturing and Assembly. 2025. doi:10.25082/rima.2025.02.002

BibTeX
@article{Obi2025,
  author = {Obi, Manghe Fidelis and Schweitzer, Shannon and Goswami, Tarun},
  title = {A Data-Driven Evaluation of ECD Measurement Techniques Across Traditional and AI-Based Modalities},
  journal = {Research on Intelligent Manufacturing and Assembly},
  year = {2025},
  doi = {10.25082/rima.2025.02.002}
}
Kostenlos starten →