Assessment of Performance Ratio Variation in a 225 kWp Rooftop PV System Exposed to Industrial Fly Ash at PT Jaya Energi
Andalasian International Journal of Applied Science, Engineering and Technology · 17.11.2026 · 6 (3) · 338-347
DOI: 10.25077/aijaset.v6i3.378 ↗Kurz gefasst
Fachartikel in der Zeitschrift Andalasian International Journal of Applied Science, Engineering and Technology, online erschienen am 17.11.2026. Verfasst von Didik Nugroho und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
This study evaluates monthly monitoring data from a 225 kWp grid-connected rooftop photovoltaic (PV) system at PT Jaya Energi, an industrial facility where boiler-derived fly ash may contribute to module soiling. Data from Huawei FusionSolar were analyzed for September-December 2025 and May-August 2026. January-April 2026 was excluded from the comparison because frequent rainfall and cloud cover could affect irradiance and remove accumulated dust. The recorded monthly Performance Ratio (PR) ranged from 54.9% to 60.3% during September-December 2025 and from 46.8% to 54.4% during May-August 2026. Within the latter period, PR decreased from 54.4% in May to 46.8% in August, a reduction of 7.6 percentage points (13.97% relative to May). This trend indicates lower recorded system performance, but it cannot be attributed exclusively to fly-ash soiling because direct soiling measurements and controlled clean/soiled comparisons were unavailable. The daily energy log recorded 0.00 kWh fed to the grid on each listed date, this supports zero recorded daily export but does not prove that instantaneous reverse power was absent at all times. The findings support further site-specific monitoring before a fixed cleaning interval or definitive zero-export performance claim is established.
Zitieren
APA
Nugroho, D., & Saputra, P. P. S. (2026). Assessment of Performance Ratio Variation in a 225 kWp Rooftop PV System Exposed to Industrial Fly Ash at PT Jaya Energi. Andalasian International Journal of Applied Science, Engineering and Technology, 6(3), 338-347. https://doi.org/10.25077/aijaset.v6i3.378
Vancouver
Nugroho D, Saputra PPS. Assessment of Performance Ratio Variation in a 225 kWp Rooftop PV System Exposed to Industrial Fly Ash at PT Jaya Energi. Andalasian International Journal of Applied Science, Engineering and Technology. 2026;6(3):338-347. doi:10.25077/aijaset.v6i3.378
BibTeX
@article{Nugroho2026,
author = {Nugroho, Didik and Saputra, Pressa Perdana Surya},
title = {Assessment of Performance Ratio Variation in a 225 kWp Rooftop PV System Exposed to Industrial Fly Ash at PT Jaya Energi},
journal = {Andalasian International Journal of Applied Science, Engineering and Technology},
year = {2026},
volume = {6},
number = {3},
pages = {338--347},
doi = {10.25077/aijaset.v6i3.378}
}
EUVIMED