EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Experimental Analysis of the Effect of Waste Heat Recovery on the Operational Performance of a Heat Pump Dryer

Solomzi Marco Ngalonkulu, Amiyou Manaka

Andalasian International Journal of Applied Science, Engineering and Technology · 17.11.2026 · 6 (3) · 318-330

DOI: 10.25077/aijaset.v6i3.353 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Andalasian International Journal of Applied Science, Engineering and Technology, online erschienen am 17.11.2026. Verfasst von Solomzi Marco Ngalonkulu und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Air-source heat pump drying (ASHPD) systems are recognised for their energy efficiency, utilising ambient air as a low-grade energy source for moisture removal in agricultural products. However, climatic conditions significantly affect their thermodynamic performance, influencing both energy consumption and coefficient of performance (COP). This study experimentally evaluated an ASHPD system with waste-heat recovery across ambient temperatures ranging from 20 deg C to -10 deg C, under open, semi-closed, and fully closed air-loop configurations. Results indicate that waste-heat recovery increased evaporator temperatures by 1.5 deg C in the semi-closed system and 9.4 deg C in the fully closed system, leading to heating capacity improvements of 6.7% and 30.7%, respectively. Consequently, COP increased by 4.2% and 16.9%. However, high condenser pressure in the fully closed configuration restricted operation to ambient temperatures above 10 deg C. As ambient temperature decreased, COP degradation was observed: 29.6% in the open system, 29.7% in the semi-closed system, and 19.9% in the fully closed system. These findings highlight the effectiveness of waste-heat recovery in improving ASHPD performance and mitigating efficiency losses under cold conditions, while emphasising the importance of selecting appropriate air-loop configurations based on climate.

Zitieren

APA

Ngalonkulu, S. M., & Manaka, A. (2026). Experimental Analysis of the Effect of Waste Heat Recovery on the Operational Performance of a Heat Pump Dryer. Andalasian International Journal of Applied Science, Engineering and Technology, 6(3), 318-330. https://doi.org/10.25077/aijaset.v6i3.353

Vancouver

Ngalonkulu SM, Manaka A. Experimental Analysis of the Effect of Waste Heat Recovery on the Operational Performance of a Heat Pump Dryer. Andalasian International Journal of Applied Science, Engineering and Technology. 2026;6(3):318-330. doi:10.25077/aijaset.v6i3.353

BibTeX
@article{Ngalonkulu2026,
  author = {Ngalonkulu, Solomzi Marco and Manaka, Amiyou},
  title = {Experimental Analysis of the Effect of Waste Heat Recovery on the Operational Performance of a Heat Pump Dryer},
  journal = {Andalasian International Journal of Applied Science, Engineering and Technology},
  year = {2026},
  volume = {6},
  number = {3},
  pages = {318--330},
  doi = {10.25077/aijaset.v6i3.353}
}
Kostenlos starten →