RESPIRATORY CAROTID DOPPLER INDICES FOR PREDICTING FLUID RESPONSIVENESS IN SEPTIC SHOCK
Proceeding of the Shevchenko Scientific Society. Medical Sciences · 29.06.2026 · 1 (78)
DOI: 10.25040/ntsh2026.01.10 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceeding of the Shevchenko Scientific Society. Medical Sciences, online erschienen am 29.06.2026. Verfasst von Ivan Yakymenko und 2 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben.
Themen: Sepsis
Abstract (Originalsprache)
Introduction
Excessive fluid administration in septic shock worsens clinical outcomes. Pulse pressure variation (PPV) is a validated predictor of fluid responsiveness but requires invasive monitoring, which is not always available.
Objective
To evaluate the diagnostic accuracy of respiratory variations in carotid peak systolic velocity (ΔCPSV) and carotid velocity-time integral (ΔCVTI), and to compare them with PPV in mechanically ventilated patients with septic shock receiving vasopressor support. Patients and Methods: In this prospective single-center cohort study (n=120), Doppler ultrasonography of the right common carotid artery was used to assess ΔCPSV and ΔCVTI, alongside PPV measurement. Fluid responsiveness was defined by a passive leg raising-induced cardiac output increase ≥12% measured by echocardiography. Diagnostic performance was assessed using ROC analysis (bootstrap BCa 95% CI), AUCs were compared using the DeLong test, and inter-observer reproducibility was evaluated using intraclass correlation coefficients (ICC) in a subsample of 50 patients.
Results
Seventy-eight patients (65%) were fluid responders, and 42 (35%) were non-responders. PPV showed an AUC of 0.94 (95% CI 0.90-0.98), sensitivity of 85.9%, and specificity of 92.9% at a 12% threshold. ΔCPSV demonstrated an AUC of 0.93 (95% CI 0.88-0.97), sensitivity of 93.6%, and specificity of 81.0% at an 11% threshold. ΔCVTI showed an AUC of 0.90 (95% CI 0.84-0.95), sensitivity of 82.1%, and specificity of 85.7% at a 12% threshold. No statistically significant differences in AUCs were observed between methods according to the DeLong test (p=0.17-0.64). The combined ΔCPSV+ΔCVTI model achieved the highest AUC—0.96 (95% CI 0.93-0.99). Both ultrasound indices strongly correlated with PPV (r=0.71 and r=0.69; p
Zitieren
APA
Yakymenko, I., Matolinets, N., & Stevens, R. (2026). RESPIRATORY CAROTID DOPPLER INDICES FOR PREDICTING FLUID RESPONSIVENESS IN SEPTIC SHOCK. Proceeding of the Shevchenko Scientific Society. Medical Sciences, 1(78). https://doi.org/10.25040/ntsh2026.01.10
Vancouver
Yakymenko I, Matolinets N, Stevens R. RESPIRATORY CAROTID DOPPLER INDICES FOR PREDICTING FLUID RESPONSIVENESS IN SEPTIC SHOCK. Proceeding of the Shevchenko Scientific Society. Medical Sciences. 2026;1(78). doi:10.25040/ntsh2026.01.10
BibTeX
@article{Yakymenko2026,
author = {Yakymenko, Ivan and Matolinets, Nataliya and Stevens, Rom},
title = {RESPIRATORY CAROTID DOPPLER INDICES FOR PREDICTING FLUID RESPONSIVENESS IN SEPTIC SHOCK},
journal = {Proceeding of the Shevchenko Scientific Society. Medical Sciences},
year = {2026},
volume = {1},
number = {78},
doi = {10.25040/ntsh2026.01.10}
}
EUVIMED