DUREZA SUPERFICIAL DE RESINAS COMPOSTAS FOTOATIVADAS COM APARELHOS FOTOPOLIMERIZADORES MONO E POLYWAVE
UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR · 29.10.2026 · 15 (17) · 1-10
DOI: 10.24980/ucm.v15i17.7083 ↗Kurz gefasst
Fachartikel in der Zeitschrift UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR, online erschienen am 29.10.2026. Verfasst von Rafael Massunari MAENOSONO und 5 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Considerando que a diversidade de formulações comerciais e de sistemas fotoiniciadores pode alterar o desempenho das resinas compostas frente a diferentes protocolos de fotoativação, este estudo teve como objetivo avaliar a microdureza Knoop de cinco resinas compostas fotoativadas com aparelhos fotopolimerizadores monowave e polywave. Metodologia: Espécimes com 10 mm de diâmetro e 2 mm de espessura (n = 10) das resinas Filtek Z350 XT (3M ESPE), Vittra APS (FGM Dental), Spectra Smart (Dentsply Sirona), Forma (Ultradent Products) e Palfique LX5 (Tokuyama Dental) foram fotoativados por 40 s com um aparelho monowave (LED azul; 1000 mW/cm²) ou polywave (LED azul-violeta; 1200 mW/cm²). Após armazenamento em água destilada por 24 h e polimento, foram realizadas três indentações Knoop por espécime (0,49 N; 15 s). Os dados foram analisados por ANOVA a dois fatores e teste de Tukey (α = 0,05). Resultados: A Vittra APS apresentou os maiores valores de microdureza (135 KHN com o aparelho monowave e 125 KHN com o polywave), seguida pela Filtek Z350 XT (106–107 KHN). Spectra Smart, Forma e Palfique LX5 apresentaram os menores valores (94–98 KHN), sem diferença estatística entre si. A fotoativação polywave reduziu a microdureza da Vittra APS e aumentou a da Palfique LX5 (p < 0,05); para as demais resinas, não houve diferença entre os aparelhos. Conclusão: O efeito do aparelho fotopolimerizador sobre a microdureza Knoop foi material-dependente. Independentemente da combinação entre resina composta e aparelho, todos os grupos apresentaram valores satisfatórios de microdureza. SURFACE HARDNESS OF COMPOSITE RESINS LIGHT-CURED WITH MONOWAVE AND POLYWAVE LIGHT-CURING UNITS ABSTRACT Considering that the diversity of commercial formulations and photoinitiator systems may affect the performance of composite resins under different light-curing protocols, this study aimed to evaluate the Knoop microhardness of five composite resins light-cured using monowave and polywave light-curing units.
Methods
Specimens measuring 10 mm in diameter and 2 mm in thickness (n = 10) were prepared from Filtek Z350 XT (3M ESPE), Vittra APS (FGM Dental), Spectra Smart (Dentsply Sirona), Forma (Ultradent Products), and Palfique LX5 (Tokuyama Dental) composite resins. The specimens were light-cured for 40 s using either a monowave unit (blue LED; 1,000 mW/cm²) or a polywave unit (blue-violet LED; 1,200 mW/cm²). After storage in distilled water for 24 h and polishing, three Knoop indentations were performed on each specimen (0.49 N; 15 s). Data were analyzed using two-way analysis of variance (ANOVA) and Tukey's test (α = 0.05).
Results
Vittra APS exhibited the highest microhardness values (135 KHN with the monowave unit and 125 KHN with the polywave unit), followed by Filtek Z350 XT (106–107 KHN). Spectra Smart, Forma, and Palfique LX5 exhibited the lowest values (94–98 KHN), with no statistically significant differences among them. Polywave light-curing reduced the microhardness of Vittra APS and increased that of Palfique LX5 (p < 0.05); no differences between the light-curing units were observed for the other composite resins.
Conclusion
The effect of the light-curing unit on Knoop microhardness was material-dependent. Regardless of the combination of composite resin and light-curing unit, all groups exhibited satisfactory microhardness values.
Zitieren
APA
MAENOSONO, R. M., ROTULO, G. H. M., SILVA, J. C. A., PARAGUASSU, S. P., ROSA, V. H. R. E., & ISHIKIRIAMA, S. K. (2026). DUREZA SUPERFICIAL DE RESINAS COMPOSTAS FOTOATIVADAS COM APARELHOS FOTOPOLIMERIZADORES MONO E POLYWAVE. UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR, 15(17), 1-10. https://doi.org/10.24980/ucm.v15i17.7083
Vancouver
MAENOSONO RM, ROTULO GHM, SILVA JCA, PARAGUASSU SP, ROSA VHRE, ISHIKIRIAMA SK. DUREZA SUPERFICIAL DE RESINAS COMPOSTAS FOTOATIVADAS COM APARELHOS FOTOPOLIMERIZADORES MONO E POLYWAVE. UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR. 2026;15(17):1-10. doi:10.24980/ucm.v15i17.7083
BibTeX
@article{MAENOSONO2026,
author = {MAENOSONO, Rafael Massunari and ROTULO, Gustavo Henrique Martins and SILVA, Juliana Casalino Amorim and PARAGUASSU, Selene Paiva and ROSA, Victor Hugo Ribeiro e and ISHIKIRIAMA, Sérgio Kiyoshi},
title = {DUREZA SUPERFICIAL DE RESINAS COMPOSTAS FOTOATIVADAS COM APARELHOS FOTOPOLIMERIZADORES MONO E POLYWAVE},
journal = {UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR},
year = {2026},
volume = {15},
number = {17},
pages = {1--10},
doi = {10.24980/ucm.v15i17.7083}
}