ANÁLISE DA POTÊNCIA DOS FOTOPOLIMERIZADORES DE CIRURGIÕES DENTISTAS EM SANTA FÉ DO SUL, SÃO PAULO E REGIÃO
UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR · 14.05.2026 · 15 (17) · 1-21
DOI: 10.24980/ucm.v15i17.6654 ↗Kurz gefasst
Fachartikel in der Zeitschrift UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR, online erschienen am 14.05.2026. Verfasst von Gabriele Oliveira AMARAL und 5 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A resina composta (RC) é amplamente empregada na odontologia por sua capacidade de imitar características dentárias e exigir preparos conservadores. Sua eficácia depende da polimerização, realizada por fotopolimerizadores, com destaque para os que utilizam Light Emitting Diode (LED), que emitem luz com menor calor e maior eficiência. A potência dos fotopolimerizadores é crucial para o sucesso das restaurações, impactando diretamente o grau de conversão de unidades fotopolimerizadoras tipo Light Emitting Diode (LED). Equipamentos descalibrados podem comprometer os tratamentos, gerando falhas como fraturas e recidiva de cárie. A pesquisa objetivou avaliar a calibração dos fotopolimerizadores de LED em clínicas de Santa Fé do Sul, São Paulo (SP), e região para verificar se estão dentro dos padrões de potência recomendados pelos fabricantes. Foram coletadas medições de potência de 80 fotopolimerizadores em diversas cidades, incluindo Santa Fé do Sul-SP, Ilha Solteira-SP, Aparecida do Taboado-MS e Santa Albertina-SP, utilizando um radiômetro para fornecer a potência real de cada dispositivo. As medições foram comparadas com a potência nominal fornecida pelos fabricantes. A análise revelou que 57,5% dos fotopolimerizadores avaliados estavam dentro dos parâmetros mínimos necessários (acima de 400 mW/cm²), enquanto 42,5% apresentaram potência abaixo desse padrão. Aparelhos com mais de 5 anos tinham maior probabilidade de estar abaixo do padrão comparados aos aparelhos com até 1 ano de uso. Nenhum aparelho teve potência exatamente igual à potência nominal especificada pelos fabricantes. A pesquisa conclui que a maioria dos fotopolimerizadores na região não atende aos parâmetros de potência recomendados, indicando a necessidade de calibração e manutenção mais rigorosas para garantir a eficácia dos tratamentos odontológicos. ANALYSIS OF THE OUTPUT POWER OF DENTAL LIGHT-CURING UNITS IN SANTA FÉ DO SUL, SÃO PAULO, AND SURROUNDING REGION ABSTRACT Composite resin (CR) is widely used in dentistry due to its ability to mimic dental characteristics and allow for conservative tooth preparations. Its effectiveness depends on adequate polymerization, which is performed using light-curing units, particularly those based on light-emitting diode (LED) technology, which emit light with lower heat generation and greater efficiency. The output power of light-curing units is crucial for the success of restorative procedures, as it directly affects the degree of conversion achieved by LED light-curing devices. Improperly calibrated equipment may compromise dental treatments, leading to failures such as fractures and recurrent caries. This study aimed to evaluate the calibration of LED light-curing units used in dental clinics in Santa Fé do Sul, São Paulo (SP), and the surrounding region, in order to verify whether they meet the output power standards recommended by manufacturers. Power output measurements were collected from 80 light-curing units in several cities, including Santa Fé do Sul (SP), Ilha Solteira (SP), Aparecida do Taboado (MS), and Santa Albertina (SP), using a radiometer to determine the actual output power of each device. The measurements were compared with the nominal power values provided by the manufacturers. The analysis showed that 57.5% of the evaluated light-curing units met the minimum required parameters (above 400 mW/cm²), whereas 42.5% exhibited output power below this standard. Devices older than five years were more likely to present substandard output compared with devices with up to one year of use. None of the devices demonstrated output power exactly matching the nominal values specified by the manufacturers. The study concludes that most light-curing units in the region do not meet the recommended output power parameters, highlighting the need for more rigorous calibration and maintenance to ensure the effectiveness of dental treatments.
Zitieren
APA
AMARAL, G. O., GARCIA, M. E., FRANCISCON, M. S., FRANCISCON, J. P. S., REZENDE, G. C., & SANTOS, A. D. (2026). ANÁLISE DA POTÊNCIA DOS FOTOPOLIMERIZADORES DE CIRURGIÕES DENTISTAS EM SANTA FÉ DO SUL, SÃO PAULO E REGIÃO. UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR, 15(17), 1-21. https://doi.org/10.24980/ucm.v15i17.6654
Vancouver
AMARAL GO, GARCIA ME, FRANCISCON MS, FRANCISCON JPS, REZENDE GC, SANTOS AD. ANÁLISE DA POTÊNCIA DOS FOTOPOLIMERIZADORES DE CIRURGIÕES DENTISTAS EM SANTA FÉ DO SUL, SÃO PAULO E REGIÃO. UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR. 2026;15(17):1-21. doi:10.24980/ucm.v15i17.6654
BibTeX
@article{AMARAL2026,
author = {AMARAL, Gabriele Oliveira and GARCIA, Matheus Esnel and FRANCISCON, Marília Soares and FRANCISCON, João Paulo Soares and REZENDE, Gabriely Cristinni and SANTOS, Alailson Domingos},
title = {ANÁLISE DA POTÊNCIA DOS FOTOPOLIMERIZADORES DE CIRURGIÕES DENTISTAS EM SANTA FÉ DO SUL, SÃO PAULO E REGIÃO},
journal = {UNIFUNEC CIENTÍFICA MULTIDISCIPLINAR},
year = {2026},
volume = {15},
number = {17},
pages = {1--21},
doi = {10.24980/ucm.v15i17.6654}
}
EUVIMED