Abstract (Originalsprache)
Objective
This in vitro study aimed to evaluate the effect of implant vertical positioning on the accuracy of digital and conventional impressions for single implants using three-dimensional superimposition analysis.Material and Methods: A master model with a single implant analog (Biohorizons, 5.7 mm) was prepared at three different gingival depths (2 mm, 4 mm, and 6 mm) in the mandibular first molar region. Digital impressions were obtained using two intraoral scanners (Trios 3Shape and Cerec Omnicam), while conventional impressions were taken using polyvinylsiloxane (PVS) and condensation silicone (Type C silicone). In total, 96 test models (n=8 per group) were generated. All models were digitized and compared to the reference STL model using reverse-engineering software (Rapidform) for 3D deviation analysis. Statistical analysis was performed using the Kruskal-Wallis and Mann-Whitney U tests (α=0.05).
Results
No statistically significant differences were observed between the digital impression groups (p>0.05). Among conventional techniques, the group using C-silicone showed significantly higher deviations than the PVS group (p
Zitieren
APA
Aslıyüce, V., Özcan, N., İren, E. Y., & Önal, B. Ö. (2026). IN VITRO EVALUATION OF ACCURACY OF DIGITAL IMPRESSIONS VERSUS CONVENTİONAL IMPRESSIONS AT VARYING IMPLANT DEPTHS FOR SINGLE CROWNS. Kırıkkale Üniversitesi Tıp Fakültesi Dergisi, 28(2), 220-226. https://doi.org/10.24938/kutfd.1836746
Vancouver
Aslıyüce V, Özcan N, İren EY, Önal BÖ. IN VITRO EVALUATION OF ACCURACY OF DIGITAL IMPRESSIONS VERSUS CONVENTİONAL IMPRESSIONS AT VARYING IMPLANT DEPTHS FOR SINGLE CROWNS. Kırıkkale Üniversitesi Tıp Fakültesi Dergisi. 2026;28(2):220-226. doi:10.24938/kutfd.1836746
BibTeX
@article{Aslyce2026,
author = {Aslıyüce, Vildan and Özcan, Nihal and İren, Elif Yiğit and Önal, Buse Özdemir},
title = {IN VITRO EVALUATION OF ACCURACY OF DIGITAL IMPRESSIONS VERSUS CONVENTİONAL IMPRESSIONS AT VARYING IMPLANT DEPTHS FOR SINGLE CROWNS},
journal = {Kırıkkale Üniversitesi Tıp Fakültesi Dergisi},
year = {2026},
volume = {28},
number = {2},
pages = {220--226},
doi = {10.24938/kutfd.1836746}
}