EUVIMEDEUVIMED entdecken
Crossref

IN VITRO EVALUATION OF ACCURACY OF DIGITAL IMPRESSIONS VERSUS CONVENTİONAL IMPRESSIONS AT VARYING IMPLANT DEPTHS FOR SINGLE CROWNS

Vildan Aslıyüce, Nihal Özcan, Elif Yiğit İren, Buse Özdemir Önal

Kırıkkale Üniversitesi Tıp Fakültesi Dergisi · 12.08.2026 · 28 (2) · 220-226

DOI: 10.24938/kutfd.1836746 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Kırıkkale Üniversitesi Tıp Fakültesi Dergisi, online erschienen am 12.08.2026. Verfasst von Vildan Aslıyüce und 3 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This in vitro study aimed to evaluate the effect of implant vertical positioning on the accuracy of digital and conventional impressions for single implants using three-dimensional superimposition analysis.Material and Methods: A master model with a single implant analog (Biohorizons, 5.7 mm) was prepared at three different gingival depths (2 mm, 4 mm, and 6 mm) in the mandibular first molar region. Digital impressions were obtained using two intraoral scanners (Trios 3Shape and Cerec Omnicam), while conventional impressions were taken using polyvinylsiloxane (PVS) and condensation silicone (Type C silicone). In total, 96 test models (n=8 per group) were generated. All models were digitized and compared to the reference STL model using reverse-engineering software (Rapidform) for 3D deviation analysis. Statistical analysis was performed using the Kruskal-Wallis and Mann-Whitney U tests (α=0.05).

Results

No statistically significant differences were observed between the digital impression groups (p>0.05). Among conventional techniques, the group using C-silicone showed significantly higher deviations than the PVS group (p

Zitieren

APA

Aslıyüce, V., Özcan, N., İren, E. Y., & Önal, B. Ö. (2026). IN VITRO EVALUATION OF ACCURACY OF DIGITAL IMPRESSIONS VERSUS CONVENTİONAL IMPRESSIONS AT VARYING IMPLANT DEPTHS FOR SINGLE CROWNS. Kırıkkale Üniversitesi Tıp Fakültesi Dergisi, 28(2), 220-226. https://doi.org/10.24938/kutfd.1836746

Vancouver

Aslıyüce V, Özcan N, İren EY, Önal BÖ. IN VITRO EVALUATION OF ACCURACY OF DIGITAL IMPRESSIONS VERSUS CONVENTİONAL IMPRESSIONS AT VARYING IMPLANT DEPTHS FOR SINGLE CROWNS. Kırıkkale Üniversitesi Tıp Fakültesi Dergisi. 2026;28(2):220-226. doi:10.24938/kutfd.1836746

BibTeX
@article{Aslyce2026,
  author = {Aslıyüce, Vildan and Özcan, Nihal and İren, Elif Yiğit and Önal, Buse Özdemir},
  title = {IN VITRO EVALUATION OF ACCURACY OF DIGITAL IMPRESSIONS VERSUS CONVENTİONAL IMPRESSIONS AT VARYING IMPLANT DEPTHS FOR SINGLE CROWNS},
  journal = {Kırıkkale Üniversitesi Tıp Fakültesi Dergisi},
  year = {2026},
  volume = {28},
  number = {2},
  pages = {220--226},
  doi = {10.24938/kutfd.1836746}
}
Kostenlos starten →