Impact of a Hospital Medicine POCUS Program on Scan Quality, Faculty Satisfaction, and Billing Revenue
POCUS Journal · 18.11.2026 · 11 (02) · 24-32
DOI: 10.24908/pocusj.v11i02.20346 ↗Kurz gefasst
Fachartikel in der Zeitschrift POCUS Journal, online erschienen am 18.11.2026. Verfasst von Thomas Heyne und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Given the lack of consensus guidelines for point of care ultrasound (POCUS) for internal medicine (IM) amongst U.S. societies, individual institutions must decide whether to adopt more or less structured approaches to IM-POCUS training, privileging, scan documentation, and quality assurance (QA). Since its inception in 2018, our IM-POCUS program has utilized highly structured guidelines, mirroring protocols suggested in guidelines from the American College of Emergency Physicians (ACEP). We sought to evaluate the impact of such a structured IM-POCUS program on faculty satisfaction, scan quality, and billing revenue.
Methods
This study used faculty surveys to (1) evaluate faculty trainee satisfaction and (2) identify barriers to training and to POCUS use. We used QA data to assess the diagnostic performance of scanning providers, including positive predictive value (PPV), negative predictive value (NPV), accuracy, and rate of uninterpretable studies, as determined by POCUS experts. Finally, we used billing data to track scan volume and billing revenue.
Results
A total of 32 hospitalists started the training pathway from 2018 to 2025. To date, 24 hospitalists have completed the training, and 4 are in progress. Of the 24 who completed training, 17 responded to a post-training survey. The majority reported that their training helped make them a better clinician (94%, 16/17), educator (94%, 16/17), proceduralist (77%, 13/17), and physical examiner (77%, 13/17), while 88% (15/17) felt it improved their job satisfaction. The top barriers to POCUS training were busy work and parental schedules. The top barriers to clinical POCUS use were the additional time required to scan and save images, and limited access to ultrasound machines. Clinical scans reviewed for QA showed an overall PPV of 99%, NPV of 97%, and accuracy of 98% (all excluding technically limited studies, TLS), and a TLS rate of 6.9%. Billing data showed a steadily increasing volume of scans and billing revenue, with 1,611 scans and revenue of $37,747 in professional fees in the most recent fiscal year.
Conclusion
Our IM-POCUS program, which is based on highly structured ACEP guidelines, has shown high faculty trainee satisfaction, good diagnostic POCUS performance, and steady growth in scan volume and revenue. This approach could serve as a useful model for other hospital medicine groups looking to build IM-POCUS training programs.
Zitieren
APA
Heyne, T., Shokoohi, H., & Liteplo, A. (2026). Impact of a Hospital Medicine POCUS Program on Scan Quality, Faculty Satisfaction, and Billing Revenue. POCUS Journal, 11(02), 24-32. https://doi.org/10.24908/pocusj.v11i02.20346
Vancouver
Heyne T, Shokoohi H, Liteplo A. Impact of a Hospital Medicine POCUS Program on Scan Quality, Faculty Satisfaction, and Billing Revenue. POCUS Journal. 2026;11(02):24-32. doi:10.24908/pocusj.v11i02.20346
BibTeX
@article{Heyne2026,
author = {Heyne, Thomas and Shokoohi, Hamid and Liteplo, Andrew},
title = {Impact of a Hospital Medicine POCUS Program on Scan Quality, Faculty Satisfaction, and Billing Revenue},
journal = {POCUS Journal},
year = {2026},
volume = {11},
number = {02},
pages = {24--32},
doi = {10.24908/pocusj.v11i02.20346}
}
EUVIMED