Detection of anemia based on blood attenuation cutoff value of combined cardiovascular structures using non-contrast chest CT
Journal of the Mexican Federation of Radiology and Imaging · 29.10.2026 · 5 (3)
DOI: 10.24875/jmexfri.m26000134 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the Mexican Federation of Radiology and Imaging, online erschienen am 29.10.2026. Verfasst von Luis G. Garcia-Armas und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
Low blood attenuation, measured in Hounsfield units (HU) on non-contrast chest computed tomography (CT), has been proposed as an imaging marker of anemia. This study evaluated the correlation between blood attenuation (HU) on non-contrast chest CT and serum hemoglobin levels, and determined the optimal HU cutoff value, based on a combined assessment of multiple cardiovascular structures, for detecting anemia in adult patients. Material and methods: This casecontrol study included adult patients who underwent non-contrast chest CT and a complete blood count within 24 hours. A region of interest (ROI) was defined in five cardiovascular structures – the ascending aorta, aortic arch, descending aorta, and the left and right ventricles – to measure blood attenuation. Correlation analyses and ROC curves were calculated to assess performance metrics for each structure and for the combined cardiovascular structures.
Results
Eighty-eight patients were included: 44 with anemia and 44 controls with normal serum hemoglobin. Mean hemoglobin levels were 9.5 ± 1.7 and 13.7 ± 1.3 g/dL, respectively (p < 0.001). A significant positive correlation was observed between blood attenuation and serum hemoglobin across all cardiovascular structures (Spearman’s ρ = 0.697-0.817; p < 0.001). In the ROC curve analysis, a blood attenuation cutoff ≤ 38.0 HU in at least three of five cardiovascular structures showed high diagnostic performance for detecting anemia, with sensitivities of 77.3% to 86.4%, specificities of 93.2% to 100%, and accuracies of 71.6% to 85.2%. Moreover, diagnostic performance increased progressively with anemia severity.
Conclusions
A cutoff value ≤ 38 HU based on combined blood attenuation measurements in at least three of five cardiovascular structures on non-contrast chest CT is a simple and reliable method for detecting anemia; the diagnostic performance of this cutoff value increases in direct proportion to anemia severity.
Zitieren
APA
Garcia-Armas, L. G., & Rebollar-Garay, O. (2026). Detection of anemia based on blood attenuation cutoff value of combined cardiovascular structures using non-contrast chest CT. Journal of the Mexican Federation of Radiology and Imaging, 5(3). https://doi.org/10.24875/jmexfri.m26000134
Vancouver
Garcia-Armas LG, Rebollar-Garay O. Detection of anemia based on blood attenuation cutoff value of combined cardiovascular structures using non-contrast chest CT. Journal of the Mexican Federation of Radiology and Imaging. 2026;5(3). doi:10.24875/jmexfri.m26000134
BibTeX
@article{GarciaArmas2026,
author = {Garcia-Armas, Luis G. and Rebollar-Garay, Omar},
title = {Detection of anemia based on blood attenuation cutoff value of combined cardiovascular structures using non-contrast chest CT},
journal = {Journal of the Mexican Federation of Radiology and Imaging},
year = {2026},
volume = {5},
number = {3},
doi = {10.24875/jmexfri.m26000134}
}
EUVIMED