Contrast-enhanced ultrasound examination of a stable functioning renal transplant. Pilot study
Medical Visualization · 05.06.2026 · 30 (2) · 76-88
DOI: 10.24835/1607-0763-1588 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Visualization, online erschienen am 05.06.2026. Verfasst von S. N. Larionova und 3 weiteren Autor:innen. Die Arbeit nennt 14 Literaturangaben.
Abstract (Originalsprache)
Objective
The lack of standardized protocols and reference values for quantitative parameters in contrast-enhanced ultrasound (CEUS) of stable functioning renal transplants limits its clinical application. This study aimed to analyze CEUS quantitative parameters in recipients with stable graft function and no significant pathology on protocol biopsy, as well as to assess inter-operator reproducibility. Materials and Methods. An interventional prospective study was conducted (October 1, 2024 – March 1, 2025). 23 patients were enrolled. CEUS was performed by Resona 7 system (Mindray, China) with a convex probe (1.2–6 MHz) and SonoVue contrast agent (Bracco, Italy). Time-intensity curve (TIC) parameters were analyzed in: ROI 1 (region of interest): cortex, ROI 2 : cortex between pyramids (renal columns), ROI 3 : pyramids, ROI 4 : combined ROI 1 +ROI 2 +ROI3. Parameters assessed: Ascending Slope (AS), Arrival Time (AT), Area Under the TIC Curve (AUC), Descending Slope (DS), mean TIC intensity (mTIC), Peak Intensity (PI), Rise Time (RT), Time-to-Peak (TTP), Wash-in Area Under the Curve (WiAUC), Perfusion Index (WiAUC/RT), Wash-out AUC (WoAUC). Analysis was performed using Contrast QA software (Mindray). Inter-operator reproducibility was evaluated via intraclass correlation coefficients (ICC) and Bland-Altman analysis (mean difference, limits of agreement).
Results
Mean TIC parameters (averaged between operators) were obtained for all ROIs. ROI 1 : excellent/good reproducibility for most parameters; moderate reproducibility for AS and DS (ICC 0.840 [0.662; 0.928] and 0.859 [0.697; 0.938]). ROI 2 : Excellent to good reproducibility; moderate for WiAUC (0.848 [0.678; 0.933]), RT (0.877 [0.733; 0.946]), WiAUC/RT (0.835 [0.628; 0.929]), AS (0.836 [0.653; 0.927]), and DS (0.777 [0.537; 0.899]). ROI 3 : Higher variability for WiAUC/RT (0.706 [0.418; 0.864]), AS (0.657 [0.351; 0.838]), and DS (0.752 [0.497; 0.887]). ROI 4 : Results comparable to ROI 1 .
Conclusion
This study is a crucial step toward standardizing CEUS for renal transplants. It establishes the first quantitative CEUS benchmarks for stable allografts without significant pathology on protocol biopsy. The low inter-operator variability supports the clinical feasibility of using absolute TIC parameters (comparison of normal vs dysfunctional grafts) across different ultrasound systems.
Zitieren
APA
Larionova, S. N., Belavina, N. I., Vetsheva, N. N., & Balter, R. B. (2026). Contrast-enhanced ultrasound examination of a stable functioning renal transplant. Pilot study. Medical Visualization, 30(2), 76-88. https://doi.org/10.24835/1607-0763-1588
Vancouver
Larionova SN, Belavina NI, Vetsheva NN, Balter RB. Contrast-enhanced ultrasound examination of a stable functioning renal transplant. Pilot study. Medical Visualization. 2026;30(2):76-88. doi:10.24835/1607-0763-1588
BibTeX
@article{Larionova2026,
author = {Larionova, S. N. and Belavina, N. I. and Vetsheva, N. N. and Balter, R. B.},
title = {Contrast-enhanced ultrasound examination of a stable functioning renal transplant. Pilot study},
journal = {Medical Visualization},
year = {2026},
volume = {30},
number = {2},
pages = {76--88},
doi = {10.24835/1607-0763-1588}
}
EUVIMED