EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The Impact of the Drive Motor Type in a Hoisting Machine on Energy Costs

Tomasz Siostrzonek, Mohammad Abu Sarhan, Marcin Nawrocki, Jakub Wójcik

Management Systems in Production Engineering · 01.12.2026 · 34 (4) · 724-735

DOI: 10.2478/mspe-2026-0059 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Management Systems in Production Engineering, online erschienen am 17.11.2026. Verfasst von Tomasz Siostrzonek und 3 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a comparative assessment of the energy efficiency and operating costs of direct current (DC) and alternating current (AC) drive systems under actual operating conditions of mine hoisting machinery. Despite the rapid development of power electronics and the increasing adoption of low-speed AC synchronous motors supplied by frequency converters, separately excited DC drives supplied by multi-pulse rectifier systems remain widely used in the Polish mining industry. The analysis is based on experimental measurements obtained from operating hoisting installations during the transportation of extracted material. The electrical energy consumption of both drive systems was determined and subsequently used to evaluate the energy cost of a single hoisting cycle and the total cost over one hour of operation comprising approximately 20 complete cycles. The results indicate that differences in energy consumption and operating costs, although relatively small for an individual cycle, become economically significant under continuous industrial operation. For the considered operating conditions and electricity tariff, the AC synchronous motor reduced the energy cost of 20 operating cycles by approximately 11% compared with the conventional DC motor. The observed differences are primarily attributable to higher electrical conversion and mechanical transmission losses in the DC drive system, as well as differences in the overall efficiency of the two drive technologies. The findings demonstrate the importance of drive-system selection in reducing the electrical energy costs of mining plants. The results provide practical guidance for modernization and investment decisions, emphasizing the potential benefits of energy-efficient drive technologies and optimized machine loading in reducing the long-term unit cost of raw material extraction.

Zitieren

APA

Siostrzonek, T., Sarhan, M. A., Nawrocki, M., & Wójcik, J. (2026). The Impact of the Drive Motor Type in a Hoisting Machine on Energy Costs. Management Systems in Production Engineering, 34(4), 724-735. https://doi.org/10.2478/mspe-2026-0059

Vancouver

Siostrzonek T, Sarhan MA, Nawrocki M, Wójcik J. The Impact of the Drive Motor Type in a Hoisting Machine on Energy Costs. Management Systems in Production Engineering. 2026;34(4):724-735. doi:10.2478/mspe-2026-0059

BibTeX
@article{Siostrzonek2026,
  author = {Siostrzonek, Tomasz and Sarhan, Mohammad Abu and Nawrocki, Marcin and Wójcik, Jakub},
  title = {The Impact of the Drive Motor Type in a Hoisting Machine on Energy Costs},
  journal = {Management Systems in Production Engineering},
  year = {2026},
  volume = {34},
  number = {4},
  pages = {724--735},
  doi = {10.2478/mspe-2026-0059}
}
Kostenlos starten →